Page 30
Dovetail
– Class I, II and III
Replacing the O-ring(s)
Visually inspect the dovetail and replace any damaged or missing o-rings.
1. Remove the blade cartridge from the control body (p. 28).
The dovetail o-rings
(1)
are located on the underside of the control body dovetail.
2. Using a sharp object, such as a scratch or piercing awl, remove the damaged o-ring(s).
3. Completely clean out the o-ring pocket with rubbing alcohol.
4. Make sure the o-ring pocket is dry.
5. Use a toothpick to apply a small amount of
LOCTITE® 480
to the pocket only.
Note:
Do not let
LOCTITE
enter the air supply hole.
6. Push the new o-ring into the o-ring pocket by hand.
Note:
Make sure the o-ring is seated flat in the pocket.
7. Let the o-ring set for a minimum of one hour.
8. Apply a light film of
Parker Super O-Lube
over each o-ring.
9. Confirm that each o-ring hole is not plugged with
LOCTITE
.
10. Replace the blade cartridge (p. 28).
Summary of Contents for Tidland Performance Series