MAINTENANCE
www.maxcessintl.com
Tidland Performance Series Automatic Knifeholder
MI 557417 1 AD
Page 28
Cant Key O-ring
The cant key must remain tight in the knifeholder body.
If the cant key becomes loose in the body or if cracks in the o-ring are visible, replace the o-ring.
Replacing the O-ring
1. Pull the o-ring straight out from the control body.
2. Remove o-ring from the cant key.
Caution!
Do not nick or otherwise damage o-ring groove
edges when removing o-ring.
3. Using Parker Super O-Lube, lubricate the new
o-ring and the cant key o-ring groove.
4. Install new o-ring into the cant key o-ring groove.
5. Select arrow orientation as described in
Cant Key
Orientation
on page 22.
6. Push the cant key straight into the knifeholder body.
Blade Cartridge
Removing the Cartridge
1. Turn the function control knob to the red (retract) position.
2. Pull the lock/unlock lever up to unlock the blade cartridge.
3. Press and hold down the safety lock pin and slide the
blade cartridge off the control body.
Reinstalling the Cartridge
1. Slide the blade cartridge onto the control body.
2. The safety lock pin will 'snap' in place when the blade
cartridge is in the correct position.
3. Pull the lock/unlock lever down to lock the blade cartridge
to the control body.
4. Confirm that the arrow on the blade cartridge is pointing in
the same direction as the arrow on the cant key.
Reversing the Cartridge
1. Follow Steps 1 through 3 above to remove the blade
cartridge.
2. Install the blade cartridge onto the control body in the
opposite direction from the way it was removed. The safety
lock pin will 'snap' in place when the blade cartridge is in
the correct position.
3. Pull the lock/unlock lever down to lock the blade cartridge to the control body.
4. Remove the cant key and replace it back in the control body, making sure that the arrow on the
cant key is pointing in the same direction as the arrow on the blade cartridge.