3-2
INSTALLATION
www.maxcessintl.com
MAGPOWR TS Load Cell
MI 850A342 1 A
Mechanical and electrical
installation
(continued)
Shaft and roll assembly (supplied by customer)
The sensor split coupling or in-roll coupling can accommodate
shaft misalignment of 0.001 mm/mm [0.001 in/in].
Example: For 600 mm between machine side frames, the sensor
must be aligned within .600 mm.
Split coupling models
Split coupling sensors can be used for both live and dead shaft
applications. All split coupling sensors are shipped with the
coupling locked in place for use with a dead shaft. For live shaft
applications remove the anti-rotation screw located behind the
removable part of the split coupling.
Remove the coupling screws and top half of the couplings. Gently
lower the shaft/roller assembly into the couplings. The couplings
have some misalignment capability to facilitate shaft mounting.
Replace one coupling top half and screws. Tighten screws
securely. Push this coupling toward the machine frame, and hold
it in position while securing the coupling on the other end of the
shaft. This will divide the thermal expansion capability between
the two sensors.
In-roll coupling models
Insert one sensor into each end of a machined tube and install between machine frames
accordingly.
52.0 +.05/-.00 mm diameter; 0.53 in. (13.5 mm) maximum depth for 5 lb, 50 lb, 2 kg, and 25 kg sensors
62.0 +.05/-.00 mm diameter; 0.76 in. (13.9 mm) maximum depth for 150, 330 and 500 lb, 75 kg, 150 and 250 kg sensors