Maxcess H3257 User Manual Download Page 11

3-3 

INSTALLATION 

www.maxcessintl.com 

Fife H3257 

MI 1-921 1 

Components and 
cable connections 

Single light source 

Dual light source 

Item  Description 

Part number 

H3257 LED Light Source 

See Table 1. 

Power/communication cable * 

29LH6610-F5M-xS 

Power supply, +24 VDC   

See page 3-2.

 

29LH6610-PWR-80W 

Termination plug (control system status relay) 

29LH6610-SR-01 

SYNC connector 

Install DC mode plug**  for DC light (non-pulsed)  OR 

290001255 

Install synchronization cable for dual light source 

29LH6610-M4M-xS 

** 

Use for connecting to power supply or another H3257. 
One DC mode plug is required for each H3257 LED Light Source 

Cable part numbers:  x= length in meters 

Figure 2.  Components and cable connections. 

Summary of Contents for H3257

Page 1: ...H3257 LED Light Source User Manual EN MI 1 921 1 FIFE GUIDING SOLUTIONS...

Page 2: ...ly 24V 3 2 Alternate power supply 3 2 Components and cable connections 3 3 Single light source 3 3 Dual light source 3 3 Using the H3109 Discriminating Detector 3 4 OPERATION 4 1 Sensor gap 4 1 Adjust...

Page 3: ...e number on the back page of this publication This LED light source must not be installed or used in a machine or system that does not comply with the machinery directive 2006 42 EC This LED light sou...

Page 4: ...ource is used as a backlight for an optical sensor or camera in a web or strip guiding system The H3257 provides uniform LED light output through a diffusing lens which is captured by a sensor or came...

Page 5: ...e following The content of these operating instructions Any safety instructions on the device The machine manufacturer s specifications All national state and local requirements for installation accid...

Page 6: ...ION General danger or important note Reference to general hazards that may result in bodily injuries or damage to device or material DANGER Danger due to voltage electric shock Reference to danger of...

Page 7: ...issioning WARNING Death or injury can result from electrical shock Turn off and disconnect the power supply before connecting or disconnecting any cable connectors Damage to the equipment caused by fa...

Page 8: ...d See Figure 1 page 3 2 WARNING Injury can result from cutting Keep hands away from moving web material Maintenance and repair WARNING Death or injury can result from electrical shock Turn off and dis...

Page 9: ...B C D E 290001165 Diffused LED Light Source 24 5 619 8 24 40 457 2 18 00 X 81 3 3 20 4 290001198 Diffused LED Light Source 47 1192 8 46 96 X 50 8 20 00 88 4 3 48 6 290001197 Diffused LED Light Source...

Page 10: ...und lug Ground to building ground bonding system per N E C or local codes Alternate power supply If using a different power supply connect the H3257 using a 5 pin M12 female to flying lead cable See T...

Page 11: ...er supply 24 VDC See page 3 2 29LH6610 PWR 80W 4 Termination plug control system status relay 29LH6610 SR 01 5 SYNC connector Install DC mode plug for DC light non pulsed OR 290001255 Install synchron...

Page 12: ...1 Always set the H3257 to intensity 8 default 2 Always set the H3257 to operate in pulsed mode default 3 A 4 7k 1 4 W load resistor must be placed across the H3109 output and COM On most controllers t...

Page 13: ...settings See Table 3 Intensity setting Relative LED drive level 1 30 2 40 3 50 4 60 5 70 6 80 7 90 8 100 default Table 3 H3257 intensity settings Intensity setting versus sensor gap Harsh or very dust...

Page 14: ...conductive tool to actuate the button Each press of the button increases the intensity level by 10 of the maximum Once the maximum intensity has been reached the intensity will revert to Setting 1 on...

Page 15: ...uired length Dual light sources must be synchronized when used with a single sensor This occurs automatically when a synchroniza tion cable is installed between the 4 pin SYNC connector of each H3257...

Page 16: ...tact Maxcess for assistance Dim section of light Open n a Damaged or broken lens n a n a H3257 faults and status contact The H3257 provides a contact closure in series with the 5 pin power connectors...

Page 17: ...r Do not soak or spray the detector with fluids Electrical damage may occur Spare parts These parts are available from vendor Description Part No 4A slow blow fuse Littelfuse Inc 0454004 MR Circular h...

Page 18: ...ault DC Light single or dual Synchronized dual Voltage input 10 VDC to 30 VDC Power requirements 5 W per 12 inches of product length Protection class IP65 Operating temperature 20 to 50 C 4 to 122 F L...

Page 19: ...replacement parts When ordering replacement parts please indicate where possible part number drawing number and model description To request service or to get replacement parts contact one of the addr...

Page 20: ...les maxcess eu www maxcess eu CHINA Tel 86 756 881 9398 Fax 86 756 881 9393 info maxcessintl com cn www maxcessintl com cn INDIA Tel 91 22 27602633 Fax 91 22 27602634 india maxcessintl com www maxcess...

Reviews: