INSTALLATION
3 - 5
DSE-22
www.maxcess.eu
MI 1081 1 A
Electrical connection
ATTENTION
The sensor could be damaged.
The safe function of the sensor and the system is only
guaranteed if it is properly installed.
Electrical connections should always be made or disconnected
on the sensor while there is no electrical power in the system.
When attaching the connector with the jack on the sensor,
pay close attention to the guide and groove! The connector and
jack must not be connected with incorrect orientation or by
force, as this will destroy the sensor.
Electrical lines must not be subjected to any mechanical
loads.
∙
The sensor must be connected to the web guide controller
according to the system diagram in the system
documentation.
only for sensor cables with open wire ends
Personnel: Qualified electrician
The sensor may only be connected electrically by a qualified
electrician.
– The power supply voltage must be externally fused.
– The external 12V/24V DC voltage must be generated and
supplied in accordance with the criteria for protective extra-
low voltage (PELV).
– The negative potential must be connected to ground.
– The sensor housing must be grounded via the cable screen.
see also the drawing for the sensor cable in the system doc-
umentation