4-8
MENU DESCRIPTIONS
www.maxcessintl.com
FIFE-500-XL
MI 2-267 1 D
OI SETTINGS Provides access to various operator interface settings.
Navigation:
MANUAL / SERVO-CENTER / AUTOMATIC
SETUP
DISPLAY
OI SETTINGS
Enable menu timeouts – Check this box to force menus to close after
a specified number of seconds. To adjust the timeout value, press the
“seconds” control and enter the desired value. Some menus are
immune from the timeout option.
Menus that are immune from timeout will show this icon in the
status bar (only when timeouts are enabled).
OI Address – Address of the OI in a networked system. Any value
between 1 and 31 is valid. The default value of 30 is recommended in
a non-networked system.
OI Termination – Should always be checked in a non-networked
system. In a networked system, should be checked if the OI is at the
end of the line and unchecked otherwise. Refer to the supplementary
user instructions, "Fife FIFE-500-XL: Networking of Web Guiding
Systems" (MI 1-919) for details.
Bargraph update speed – This slider controls the update speed of the
sensor signal bargraph on the Operator Level screen.
Default Connection – To specify which device this OI should connect
to when power is applied.
Specified device – The Operator Interface will always connect
to the drive address specified in the associated edit control.
First device found – The Operator Interface will connect to the
first drive it finds in the network.
Last connected device – Connect to the same drive the
Operator Interface was connected to when powered off.