background image

P/N 07823145 Rev D   Page 1

2271PB-07 Hood 

Instructions For Use

              
                 

WARNING

Use only if package is received unopened and contents are  

undamaged. If damage is noted, contact the shipper for replacement 

or repair.

 

Prior to using any MAXAIR

®

 System or component, be sure to be 

familiar with the system’s NIOSH approved configuration.

 

DO NOT use if any component is damaged.  If any components are 

damaged or contaminated and therefore unfit for safe and effective 

use, they should be replaced immediately.
Only trained and experienced personnel who have read and under-

stand the User’s Instructions should use this product.

 

Failure to follow the User’s Instructions, these and in the MAXAIR 

Systems User’s Instructions, P/N 03521015,  may be hazardous to 

the user’s health.

 

The institution using this product in any application is responsible for 

determining the appropriateness of this equipment relative to regula-

tory requirements. Bio-Medical Devices Intl, Inc. does not recom-

mend the appropriate systems for a particular institution or facility.

 

Use only MAXAIR Systems/ NIOSH approved compatible  

components.

 

NOT for use in atmospheres immediately dangerous to life or health 

(IDLH), and atmospheres containing less than 19.5% oxygen, or 

more than 25% oxygen.

Flammability Level I: fabric may burn if exposed to open flame.

 

Follow current local regulations governing biohazard waste to safely 

dispose of used shrouds.
If you need more information, contact your BMDI Sales  

Representative, or call BMDI customer service at 1-800-443-3842.

 CAUTION 

 

Before use, refer to the CAPR

®

 User’s Instructions, P/N 03521015 (received with all CAPR Helmets) for details. 

 

      

               

!

Symbol Definitions

                    

                  Warning, Caution, or Note                        Order Number

 

      

               

!

 

      

               

!

Intended Use

 

 

The MAXAIR

®

 CAPR

®

 Hood Systems are intended to filter 

 

aerosolized and droplet particulates and provide high level fluid 

resistance.
Hoods are designed for single use applications.

Hood Specifications

Temperature Limits:

 49

0

C maximum

Materials:

Regulatory 

 NIOSH             

Typical Hood System Components

1 The 2500-30TSC is an alternate to the 2500-37TSC.

MATERIAL

TYPE

FLUID RESISTANCE

Body (Shroud) Polypropylene 

ASTM F1671

Lens

Polycarbonate

ASTM F1671

Hood Filter

Polypropylene

AATCC TM127

HLF

Polypropylene/  

modacrylic blend

General particle filter 

material

O.N.

1. 2081-03 Helmet 

2. 2271PB-07 Hood w/2170-27 HLF

3. 2061-05 HFR FCC

4. 2500-37TSC Battery

1

5. 2000-76 Battery Belt

6. 2600-01 Battery Charger

1

2

3

4

5

6

O.N. 2271PB-07SM

 

(Small-Medium)

P/N 07831155

O.N. 2271PB-07ML

 

(Medium-Large)

P/N 07831156

*one 2170-27 (07831205) HLF is 

included with each Hood

Reviews: