Connection of the hob
The ceramic hob can be connected in different ways (230V~ 1P+N or 400V~ 2P+N), use the
brass links which are in the box next to the terminal block.
Monophase 230V~1P+N
Put the link bar between terminal 1 and 2
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Caution!
Frequent loosening and screwing of the screws on the connection box risks
damaging the efficiency of the tightness once screwed. It is therefore
advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.
We cannot be held responsible for any accident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection