4. Adjust Red and Blue with Green line at centre of the screen by rotating
(RB)-G static convergence magnetic rings.
5. Lock convergence magnets with silicone sealer.
6. Remove the DY wedges and slightly tilt the Deflection Yoke vertically
and horizontally to obtain the good overall convergence.
Fig. 9
7. Fix the Deflection Yoke by reinserting the DY wedges. Refer to Fig. 10.
8. If purity error is found, repeat “Colour Purity” adjustment.
Adjustment of CRT VRS
1. Preparation
A. Set DY to CRT not to tilt up and down left and right deflection.
B. Set CY to CRT and set CY magnet primarily (Fig. 1)
Purity magnet : Set purity magnet that 2 magnets are (TOP POSITION)
VRS magnet : Set purity magnet 2 magnets are (HORIZONTAL
POSITION)
10