3 Normal Operation
3-3
3-3-3
OVP(Over Voltage Protection) Setting
OVP protects the load from programming errors, wrong voltage setting or power source
failure.
1.
Turn the OUTPUT switch OFF.
2.
Pressing the OVP setting switch and keeping it pressed indicates the OVP set voltage on
the voltmeter of the display. Turn the OVP setting volume to adjust the voltage to the
desired value.
3.
Turn the output voltage setting dial counterclockwise all the way (minimum).
4.
Turn the OUTPUT switch back ON, increase the output voltage gradually and make sure that
the output is shut down at the set OVP voltage.