About the connection of the power supply cable 

Connection  of  the  power  cable  should  be  done  by  an 
electrician or someone who has equivalent knowledge and 
is familiar with the correct usage and danger of the product. 
Refer  to  the  page  about  connection  of  the  input  cable  in 
the  instruction  manual  and  carry  out  work.  For  products 
that have acquired safety standards, also refer to the page 
describing overvoltage categories. 

 

About input voltage 

For  the  input  voltage  of  the  product,  refer  to  the  page 
describing  the  input  terminal  of  the  product  and  the  input 
voltage  in  the  instruction  manual.  Do  not  supply  input 
exceeding the specifications of the product. 

 

About the fuse 

The  product  contains  a  protective  fuse.  In  the  case  of  a 
product in which a fuse holder is arranged externally, it is 
possible to replace the fuse. For the replacement method, 
refer to the instruction manual. 
If  the  product  does  not  have  a  fuse  holder  externally,  the 
user cannot replace the fuse. If the fuse blows out, do not 
open  the  case  or  panel,  please  contact  our  sales 
representative. 
 

Do not modify or damage the cable. 

It may cause electric shock and fire. 
 

Designed for indoor use 

Use  the  product  indoors.  Do  not  use  it  outdoors  or  indoors 
where  there  is  a  possibility  of  water  leakage,  flooding,  or 
crown. 

 

About operating temperature and humidity 

Use  within  the  range  of  operating  temperature  and 
humidity stated in the instruction manual. 
Do  not  use  it  in  a  place  where  the  ambient  temperature 
becomes  higher  than  the  operation  temperature  of  the 
product or in a narrow closed place. 

 
Do not install in places that cause condensation. 

Do not install it in places that cause condensation, where it 
is exposed to steam or water vapor. 
Insulation deteriorates, causing breakdown, electric shock, 
or fire. 
 

Do not place anything on top of the product. 

Falling or collapsing is dangerous. 
 

Do not put any objects on or in the product. 

Do  not  put  any  objects  such  as  metal  or  liquid  in  the 
product through the inlet etc.    Failure, electric shock, fire 
may result. 
 

Operate the product with your right hand. 

In case of electric shock when manipulating the product, in 
order  to  reduce  the  risk  of  current  flowing  through 
important organs of the body, Keep your left hand off from 
the product and operate with your right hand. 
 
 
 

 
 
 
 

 

Do  not  touch  the  wiring  or  load  connected  to  the 
output terminal or output terminal during operation or 
immediately after output stop. 

Very high voltage is applied to the terminals during normal 
operation  and  trial  operation.  Touching  it  will  result  in 
electric shock. 
In addition, since a capacitor is connected to the terminal, 
high  voltage  remains  on  the  terminal  even  immediately 
after stopping the output.    To avoid electric shock, do not 
touch the terminals. 

 

Turn off the power when touching the terminal. 

Before  touching  the  terminals  of  the  product,  turn  off  the 
power and check that the power has actually turned off. 
There  is  a  capacitor  at  the  terminal,  and  it  is  particularly 
dangerous  to  touch  it  immediately  after  turning  off  the 
power  supply.  Be  careful  of  the  electric  charge  of  these 
capacitors  and  connect  it  to  earth  to  discharge  it 
completely. Remove input line (AC line) during work. 

 

 

 

Install horizontally. 

Do not  install the product in the reverse direction and the 
lateral direction. 
Internal  heat  dissipation  becomes  insufficient,  parts 
deteriorate, there is a risk of smoke and fire. 

 

Do  not  install  in  the  place  where  cool  air  blows 
directly. 

There  is  a  danger  of  condensation,  leakage  current  and 
burnout. 

 

Do  not  install  the  product  in  places  around  corrosive 
gas or liquid and places where chemicals handled. 

There is a danger of parts being deteriorated, smoking and 
burning. 

 

Avoid using it in a place with much dust. 

If dust accumulates in the air inlet, remove it promptly. If dust 
accumulates in the air inlet, cooling of the product is hindered 
and it may cause malfunction. 

 

Do not block intake port and exhaust port. 

Secure more than 30cm space on the front and back of the 
product. 
If the intake port and exhaust port are blocked, the specified 
performance  of  the  product  cannot  be  demonstrated  and 
parts are deteriorate, which may cause smoke and fire. 

 

When  work  such  as  welding  is  conducted  near  the 
product, disconnect all the wires from the product. 

 

Do not wipe with chemicals (thinner etc.) or wet cloth. 

There  is  a  danger  of  electric  shock,  electric  leakage, 
burnout from chemicals or water entering the inside of the 
product. 
 

 

Summary of Contents for DRK4k Series

Page 1: ... unavailable please contact our sales representatives Keep the manual with you so that you can read it whenever you want https www matsusada com product Table of Contents 1 Introduction 1 2 Accessories 1 3 For Safe Use 2 4 Initial Inspection 5 5 Simple operation from turning on the unit to outputting from the unit 5 6 Main and Protection Functions 5 7 External View 5 7 1 Connecting the cable for p...

Page 2: ...der the supervision of those who are familiar with the proper use and danger of the product Persons with the exception of the above must not handle the product Do not open the product case and panel Do not disassemble remodel or repair by opening the product case and panel yourself There is a high voltage area inside which may possibly cause electric shock and fire Never remove the case and panel ...

Page 3: ... the product in order to reduce the risk of current flowing through important organs of the body Keep your left hand off from the product and operate with your right hand Do not touch the wiring or load connected to the output terminal or output terminal during operation or immediately after output stop Very high voltage is applied to the terminals during normal operation and trial operation Touch...

Page 4: ...e lifetime of fan varies greatly depending on the environment where it is used temperature humidity dust etc In order to use the product for a longer time it is necessary to replace the fan periodically For replacement please contact our sales office replacement require separate repair charges The replacement will require a separate repair fee There is a risk of electric shock do not replace it by...

Page 5: ... terminal block can be used The rating of the front outlet is 250V 15A Make sure that the output has already been turned off with the OUTPUT switch OUTPUT LED Off Press the PROTECT switch and then turn the numerical value setting encoder It is set to the maximum at the factory shipment Press VLT switch and FRQ switch and then turn the numerical value setting encoder to set your desired voltage and...

Page 6: ...dition The overload condition is determined by the settings of OCP and OPP 1 Press and hold the DISP key 2 After shifting to the Configuration screen turn the numeric value setting encoder clockwise to set the value to Cut off 9 LOCK Function Function Description Setting Key lock Lock all operations except for the OUTPUT switch and ENT LOCK key Press and hold the ENT LOCK key until the LK appears ...

Page 7: ...etting minimized Are settings for Ilimit OCP and OPP minimized Is the OVP setting correct Is the LOCK function activated Breaker trips Have you replaced the original screws of the housing with different ones The replaced screws may have cut into the internal circuits Is the breaker s base capacity sufficient Are the inputs and outputs connected incorrectly Output voltage fluctuates or cannot be co...

Page 8: ...8 ...

Reviews: