DJOP

series

±10

7

±20

14

±30

21

±60

42

DJOP10-5

DJOP20-3

DJOP30-2

DJOP60-1

±5

3.5

±3

2.1

±2

1.4

±1

0.7

50

60

3

DC to 30

Please consult with our sales office about the specifications except the following list.

Four-quadrant fast response

bi-polar power supply

DJOP series is 

four-quadrant bi-polar power supply which source and sink electric power

. They can be used in 2-mode of a 

constant voltage (CV) or a constant current (CC). Thanks to the original design, phenomenal light weight and compact size power 

supply, which is 140mm width, and weigh 3kg has been achieved. They are ultra compact and high speed, driving output propor-

tional to the input waveform such as a sine wave, triangular wave, saw wave, and square wave. All the models are completely 

solid-state with output voltage between ±10V to ±60V.

DJOP series is most appropriate for evaluation test such as solar panels, the instruments driven by battery and the IC which 

control battery.

Even faster model, DOS series, amplifier with function generator, 

DOPF series, or more high power model, DOP series, are available.

Contact to local sales office for details.

Applications

Features

Lineup

Suitable to evaluate battery driven equipment to use as a simulated battery

Inductive load such as coil and transformer

Capacitive load like capacitor

Various motor tests

voltage regulation tests for in-vehicle electrical component

Evaluation test for solar panel related devices

For surface treatment

Wide lineup

Select a model fitting for your applications from the lineup of various 
output voltage and current.

DC bias

10-turn potentiometer to be used for the output setting volume when used 
as the DC power supply and for the bias setting when used as AC power 
suppluy is equipped.

DC output meter

3-digit digital meter displays the DC value of the output voltage and 
current. (The option of rms indication is available.)

Constant voltage (CV) / Constant current (CC)

A single switch selects between CV and CC modes.

Four-quadrant action

DJOP Series can be used both as a high speed response DC power 
supply and as an electronic load.

Complete protective function

Protective function against over voltage/current and protective 
measures against output short-circuit are completely provided.

Master-slave

The option of Master-slave control will resolve power shortages.

Compact & light weight

For maximum compactness and light weight, DJOP Series has been 
improved for small footprint and easy carry.

Response speed

Newly developed DJOP Series is the most appropriate for transient 
response test with such high power and broad bandwidth.

Model

Weight

kg

Output voltage

V(rms value)

Output current

A (rms value)

Output power

W

Frequency bandwidth

kHz (-3dB)

Summary of Contents for DJOP Series

Page 1: ...gh speed bi polar power supply DJOP Series www matsusada com Four quadrant fast response bi polar power supply DJOP series Output voltage 0V to 60V Maximum output power 60W Frequency bandwidth DC to 30kHz NEW NEW ...

Page 2: ...d transformer Capacitive load like capacitor Various motor tests voltage regulation tests for in vehicle electrical component Evaluation test for solar panel related devices For surface treatment Wide lineup Select a model fitting for your applications from the lineup of various output voltage and current DC bias 10 turn potentiometer to be used for the output setting volume when used as the DC po...

Page 3: ...urrent The standard over current protection limits the static current responding at around 1ms Additional high speed over current protection can limit pulse current of square waveforms or from capacitor at approx 2 times more current of rating DOP series is equipped with over voltage protection which protects load by limiting voltage up to approx 120 of the rated output voltage even at abnormal co...

Page 4: ...l of output voltage V when CV control is selected and output current A when CC control is selected CV CC setting selection Use of BIAS In CV mode In CC mode When the BIAS ON OFF switch is flipped to ON bias can be changed with the BIAS setting dial Bias of the voltage can be set when CV control is selected and that of the current can be when CC control is selected Vcon Output voltage Output curren...

Page 5: ...width higher enough than the operating frequency In case of using sine waves 3 to 5 times more frequency bandwidth is required and around 10times more in case of square waves in general Inadequate bandwidth causes not only decrease in the output amplitude but much difference between the input and output phases Therefore operating the product while monitoring the actual output waveforms is recommen...

Page 6: ...be defective as satisfactory to us we at our sole discretion repair or replace such defective Products at no cost to the purchaser We assume no liability to the purchaser or any third party for special incidental consequential or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied including with...

Reviews: