64 Appendix B: Technical information
The auxiliary signals are path independent; regardless of the acquisition path that
is being used to grab images, any of the auxiliary signals can be used. For more
information, see the
section in
chapter for supported functionality.
The pinout for auxiliary I/O connector 0 is as follows. Auxiliary I/O connectors
1, 2, and 3 have the same pinout as auxiliary I/O connector 0, except you must
add 8, 16, or 24, respectively, to the number at the end of their hardware signal
name and MIL constant. For example, AUX(TRIG)_TTL_IO_4 on connector 0
would be AUX(TRIG)_TTL_IO_12 on connector 1.
1
5
15
10
11
6
Pin
Hardware signal name
MIL constant for
auxiliary signal
Description
1
AUX(TRIG)_TTL_IO_4
M_AUX_IO4
TTL auxiliary signal 4 (input/output), which supports: timer output
(M_TIMER1/M_TIMER2/M_TIMER3/M_TIMER4), trigger input, user input, or user
output (M_USER_BIT4).
2
AUX(TRIG)_TTL_IO_5
M_AUX_IO5
TTL auxiliary signal 5 (input/output), which supports: timer output
(M_TIMER1/M_TIMER2/M_TIMER3/M_TIMER4), trigger input, user input, or user
output (M_USER_BIT5).
3
AUX(TRIG)_TTL_IO_6
M_AUX_IO6
TTL auxiliary signal 6 (input/output), which supports: timer output
(M_TIMER1/M_TIMER2/M_TIMER3/M_TIMER4), trigger input, user input, or user
output (M_USER_BIT6).
4+,5-
AUX(TRIG)_LVDS_IN2
M_AUX_IO2
LVDS auxiliary signal 2 (input), which supports: trigger input, user input, or
rotary/linear encoder input bit 0.
6+,8-
AUX(TRIG)_LVDS_IN3
M_AUX_IO3
LVDS auxiliary signal 3 (input), which supports: trigger input, user input, or
rotary/linear encoder input bit 1.
7
GND
N/A
Ground.
10
GND
N/A
Ground.
12+,11-
AUX(TRIG)_OPTO_IN1
M_AUX_IO1
Opto-isolated auxiliary signal 1 (input), which supports: trigger input or user input.
13+,14-
AUX(EXP)_LVDS_OUT7
M_AUX_IO7
LVDS auxiliary signal 7 (output), which supports: timer output
(M_TIMER1/M_TIMER2/M_TIMER3/M_TIMER4) or user output (M_USER_BIT7).
15+,9-
AUX(TRIG)_OPTO_IN0
M_AUX_IO0
Opto-isolated auxiliary signal 0 (input), which supports: trigger input or user input.
Summary of Contents for Matrox Rapixo CXP
Page 6: ......
Page 18: ...18 Chapter 1 Introduction ...
Page 30: ...30 Chapter 2 Hardware installation ...
Page 54: ...54 Appendix A Glossary ...
Page 68: ...68 Appendix B Technical information ...
Page 75: ...Limited warranty Refer to the warranty statement that came with your product ...
Page 76: ......