11.1 SOFTWARE UPGRADE INSTRUCTIONS
CHAPTER 11: SOFTWARE UPGRADE GUIDE
* An AC power cord is required to update software in the field. Plug in the unit prior to beginning the update procedure.
** All plug ins must be removed prior to updating software (for example, no IPod can be connected). Do not use the console while an
update is in process.
*** If VA is installed on the console, wait until the Virtual Active icon on the standard display picture turns red prior to updating the
software.
1) Copy five software files (SirF7xAll.cab, NK, IO_XXX, updateLMM.cofige, and Extract_CE) onto a USB drive.
2) Turn on the power to the Bike, wait until the standby picture has come up (Figure A).
3) Insert the USB drive into the USB Port in the console (Figure B).
4) After a few seconds, the Bike will run the auto update processing (Figure C). The achieved percentage of the scheduled process will be
displayed (Figure D).