![Matrix U5x-05 Service Manual Download Page 25](http://html1.mh-extra.com/html/matrix/u5x-05/u5x-05_service-manual_1740473025.webp)
22
CHAPTER 8: TRoUBlESHooTINg
8.5 TRoUBlESHooTINg - ERRoR 0248
fIgURE A
fIgURE B
ERRoR CoDE 0248
1) SyMPToM:
0248 - Battery disconnection or fail. (When power is on, LCB battery voltage is less than 6 VAC).
2) SolUTIoN:
1) Please check the battery wire connection between the battery and LCB (Figure A).
2) Check the battery voltage (Figure B), if it is less than 6 V, please plug in the power cord to charge battery for 1 hour. Replace the battery if it
will not hold a charge.
3) If the battery voltage is more than 6 V, replace the LCB.
Summary of Contents for U5x-05
Page 1: ...U 5 x 0 5 B I K E S E R V I C E M A N U A l...
Page 4: ...1 1 1 Serial Number Location Chapter 1 Serial Number Location fRAME Serial number location...
Page 17: ...14 8 1 Electrical Diagrams Chapter 8 Troubleshooting...
Page 18: ...15 Chapter 8 Troubleshooting 8 1 electrical diagramS CONTINUED...
Page 21: ...18 8 1 Electrical Diagrams CONTINUED Chapter 8 Troubleshooting PULSE extended WIRE...
Page 72: ...69 NOTES...