Top cover switch
Flag
①
Reset button
6.3
C-1 top cover open
When the top cover is opened, it will come up C-1. If the flag didn’t press the
switch or the switch broken, it will come up the C-1 as well.
6.4
E-1elevator error
!6"
When feeding table gets stuck at the bottom, we can restart the machine. Then
press the start button and reset button at the same time.
!-"
When feeding table gets stuck on the top, we can restart the machine. Then
press the stop button and reset button at the same time.
6.5
C-6 Double or multiple feed
!("
The machine didn’t have double feed detecting sensors on it.
!)"
Adjust the knob or blower by flowing the instructions in section 5.1.1 and
5.1.2.