Ventilation
All rooms require a window or equivalent (e.g. a door) which can
be opened. Some rooms require a permanent vent in addition to a
window (see below).
This unit must not be used in a room which is less than 5m³. The
following table details the requirements based on the kitchen volume
(L x W x H) in m³.
The above requirements also allow use of a gas oven and grill but if
there are any other fuel burning appliances in the same room, consult
the relevant British Standard (BS5440-2:2000) or appropriate Gas Safe
document.
Flexible gas hoses complying with BS669-1 may be used in situations
where the ambient temperature of the hose will not exceed 70C.
Please note that gas hoses designed for natural gas use only must
not be used for supplying LPG.
LPG hoses can be identified by either a red band or stripe on
the outer coating of the hose. The hose should be positioned in
accordance with current gas regulations.
Room Volume
(m³)
Air Vent Req (cm
3
)
Less than 5
100
5 to 10
50
10 or more
No permanent vent
if a door or window
opens to the outside