Matrix COSEC PATH DCCE Quick Installation Manual Download Page 12

P H Y S I C A L

E N V I R O N M E N TA L

Exit Switch Port

Door Status Sense

Door Lock Relay

Door Lock Power

Aux Input Port

Aux Output Port

Dimensions
(LxHxD)

Weight

Operating
Temperature

Storage
Temperature

Humidity
Range

No

No

Yes 

(2 State)

Yes
(Internal;12 VDC @0.5A)

Yes

Yes

DCFX: 50mm x 159mm x 42mm

5% to 95 % RH Non-Condensing

Minus 20° to 60°C

 

0° to 50°C

I N / O U T

SPECIFICATIONS

DCFM

DCFI

DCFE DCCE

DCCM

DCCI

COSEC PATH DOOR Controller Variants

0° to 45°C

DCCX: 50mm x 136mm x 33mm

DCFX: 375g

DCCX: 154 g

Technical Specifications-Reader

24

23

G E N E R A L

Credential
Supported

Input Power

Communication

Built in WiFi

Built in Bluetooth

Types of Card

Buzzer

COSEC PATH Reader Variants

Ethernet & RS-485

EM Prox

Card &
Finger-
print

Card

Card &
Finger-
print

Card &
Finger-
print

LED

Tamper Detection

RDFE

RDCE RDFM RDCM RDFI

RDCI

SPECIFICATIONS

12 VDC @0.250A

No

HID i-class

Yes

Yes

Yes (2 LED with Tri-colour)

No

Card

Card

**The COSEC PATH V2 Door Controller is much similar to the COSEC PATH V1 
with the major  improvements in its Processor and Communications.

**The COSEC PATH V1 variants has the User Capacity of 10,000 and  Event 
Storage capacity of 50,000. Also, the communication facility with Wi-Fi and 
Bluetooth as well as the battery backup is not present in the PATH V1 Door 
Controller.

**The above listed technical specifications of Door Controller is for the
COSEC PATH V2 variants. 

 MIFARE

R

Summary of Contents for COSEC PATH DCCE

Page 1: ...materials or inflammable goods such as drapes Where volatile gas and or inflammable gas is created Installing and servicing should be done only by qualified technician There are no user serviceable p...

Page 2: ...ithout the prior written consent of Matrix Comsec Warranty Limited Warranty Valid only if primary protection is provided mains supply is within limit and protected and environment conditions maintaine...

Page 3: ...1 0 25W RS 485 Termination Resistor COSEC PATH Unit Mounting Plate 2 Screws 5 25 2 Screw Grips 15 Pin CDC to CDC Cable Assembly 15 Pin CDC Converter Cable Assembly A Power Hand Drill A wire Stripper A...

Page 4: ...hite Yellow Blue EXTERNAL READER COM1 COM2 Green Yellow COM2 Yellow COM1 Green RX Blue RX Light Blue TX Brown TX Light Brown PWR 12V LOCK GND Red EM LOCK SIGNALS 12V LOCK Red GND DOOR STS GND RLY NC G...

Page 5: ...Controller RS 485 COSEC PATH RDF RDC Rear View X X 1 1 Brown GND Black White Light Brown RS232 TX Rs232 RX GND TMPR NC NO W DATA1 W DATA0 HOLD BEEPER ALARM STATUS RED LED GREEN LED GND 12VRDR Grey Pi...

Page 6: ...ep 1 Trace holes A B C and Drill along the markings as shown below A C B DCFX Mounting Plate A C B DCCX Fix Mounting Plate with supplied screw grips screws as illustrated below Step 2 DCFX DCCX A C B...

Page 7: ...DCCX DCFX DCFX 2 Align COSEC PATH on mounting plate and slide it downwards as shown below DCCX Fix the Mounting Hook here When in place tighten captive screw at bottom Step 4 14 13...

Page 8: ...CFX A B Duct Box Base Plate Fix the Mounting Plate on Duct Box Top Cover Step 2 A B Duct Box Top Cover Mounting Plate DCFX The duct box shown in the illustration is not a part of the product package a...

Page 9: ...and lead them through the bottom opening of Duct Box as shown below Step 4 1 Fix the Top Cover to Base Plate by sliding Mounting Hook of top cover into the Mounting Slot of base plate 2 Tighten screws...

Page 10: ...DCFX DCCX Connecting PATH with a COSEC Server As a Direct Door Ethernet Switch Ethernet Switch COSEC Panel RS 485 COSEC Application Server Up to 32 Up to 255 As a Panel Door 20 19...

Page 11: ...de Orange ON LED Indication Device Status LED Status Indicators Technical Specifications Door Cntroller G E N E R A L User Capacity Credential Supported Input Power Communication Built in WiFi Built i...

Page 12: ...Built in WiFi Built in Bluetooth Types of Card Buzzer COSEC PATH Reader Variants Ethernet RS 485 EM Prox Card Finger print Card Card Finger print Card Finger print LED Tamper Detection RDFE RDCE RDFM...

Page 13: ...70 g RDCX 180 g 26 25 At the end of product life cycle batteries soldered boards metal components and plastic components must be disposed through recyclers If you are unable to dispose off the product...

Page 14: ...www matrixaccesscontrol com Head Office 394 GIDC Makarpura Vadodara 390010 India Ph 91 1800 258 7747 Email Support MatrixComSec com MATRIX COMSEC V 2 December 2020...

Reviews: