background image

Matrix Switch Corporation

MSC-XD3232L

Product Manual

2RU 32 input 32 output 3G-SDI Video Router with Button Control Panel

Revision 1.8

Page 1 of 61

© 2013-2019 Matrix Switch Corporation

www.matrixswitchcorp.com

Summary of Contents for MSC-XD3232L

Page 1: ...ix Switch Corporation MSC XD3232L Product Manual 2RU 32 input 32 output 3G SDI Video Router with Button Control Panel Revision 1 8 Page 1 of 61 2013 2019 Matrix Switch Corporation www matrixswitchcorp...

Page 2: ...ALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life su...

Page 3: ...commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Ad...

Page 4: ...anging a connection 14 2 2 2 Loading a preset 14 2 3 Presets Tab 14 2 3 1 Loading Work Matrix from a source target 15 2 3 2 Saving Work Matrix to a target 15 2 3 3 Usage scenarios 15 2 4 Labels Tab 15...

Page 5: ...and 37 3 11 21 PAdd Command 38 3 11 22 PairIO Command 38 3 11 23 PanelCmd Command 39 3 11 24 PanelCmdEn Command 40 3 11 25 PanelCond Command 40 3 11 26 PanelDis Command 41 3 11 27 PanelExtEn Command 4...

Page 6: ...very procedure 53 4 3 TFTP Software 54 4 3 1 Windows 54 4 3 2 Mac OS X 55 4 3 3 Linux 55 5 Troubleshooting 57 5 1 Unknown IP address 57 5 2 Unexpected reboots 57 6 Reference 58 6 1 Specifications 58 6...

Page 7: ...lization on each input can equalize input signals from Belden type 1694A cables up to lengths of 400m SD 140m HD and 120m 3G SDI BNC Video Outputs Connect SDI destinations to output connectors using 7...

Page 8: ...active at a time indicated by it being lit The current connection status for the active output is indicated by the relevant numbered input button being lit Pressing an input button will cause that in...

Page 9: ...udes DHCP enable IP address Netmask and Gateway settings DHCP should only be used for assigning specific network settings from a central DHCP server or when assigned IP addresses can be determined oth...

Page 10: ...which take effect immediately a reboot is not required Refer to the Config Tab Button Panel Settings section for more details on configuring the Remote Router IP Address Refer to the Network Planning...

Page 11: ...the IP network the default of 255 255 255 0 is for class C which accommodates up to 254 addresses The Gateway setting is required to be set to the IP address of the network gateway on remote panels wh...

Page 12: ...nations sources and or levels Example use scenarios Utilize an 8x1 remote panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router t...

Page 13: ...lines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 Sys...

Page 14: ...e Destination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the L...

Page 15: ...o a Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets T...

Page 16: ...umns for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to...

Page 17: ...characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all Routers 3D I O Pairing Enable p...

Page 18: ...panels control different levels of a Video Audio Router Control Mode Set the matrix control mode only present on Routers Available options include Local Button panel controls the router itself Remote...

Page 19: ...Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all comman...

Page 20: ...without modification using this protocol For information about other third party control system manufacturers who support MASCOT contact Matrix Switch Corporation 3 1 Protocol Changes As new commands...

Page 21: ...nd prompt character 3 3 Serial Access Matrix Switch router systems come equipped with a serial port which can be used as another means of sending Mascot commands Connect a Computer system to the devic...

Page 22: ...ters ASCII 13 followed by ASCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive additional commands If an error occur...

Page 23: ...hesis Arg Square brackets indicate an optional argument and parenthesis indicate a required argument Any optional argument specified requires that all prior optional arguments are also specified Table...

Page 24: ...arameter values Set Parameter Value Set Active Stored parameter value depends on parameter SetA Parameter Value Set Active value of a parameter only SetS Parameter Value Set Stored value of a paramete...

Page 25: ...erface mask pnl cmdEn Boolean RW AS Panel command macro enable pnl ip IP RW AS Remote IP address for panel interface to control sys arch String R System architecture Pyxis Carina Lynx etc sys firmware...

Page 26: ...dEn 0 1 Enable panel button GPIO command macros PanelCond Button Cond Panel button GPIO status conditions PanelDis 0 1 Internal panel button interface disable PanelExtEn 0 1 External panel interface e...

Page 27: ...ames Command Routers and MSC GCP2U32 only Query or assign destination names This command has 4 variations described by the following table Destination names are saved and recalled on power up Command...

Page 28: ...ss to use when accessing the Web Page or other control interfaces In the event that the IP address or Netmask of a system is unknown consult the Unknown IP Address section for this device Command Desc...

Page 29: ...e router will synchronize to when using the RemoteSync command This can also be enabled on Router systems with a local button panel to configure the Router s panel to control a different Router set to...

Page 30: ...ee System Parameters for more details Command Description Get Display all system parameter Active values Output consists of one parameter per line with the parameter identifier separated by an equals...

Page 31: ...E Superseded by the net ip System Parameter Query or assign the system IP address This setting is saved and recalled on power up WARNING Maintaining the ability to access a device s web page and for R...

Page 32: ...Command Routers only Protocol version 3 0 Query or assign matrix destination mappings Destination mappings provide a means to remap logical destinations to different physical destinations for an added...

Page 33: ...of convenience when allocating and defining system I Os Command Description MapSrc Display source matrix map Only sources are shown which have been remapped One source number per line is shown separa...

Page 34: ...ix dimensions labels current matrix state and preset data The information to return is specified by the sum of the flags values listed in the following table Flag Information Fields in JSON data 1 Ret...

Page 35: ...NAME NAME Table of information on values in capital letters above Label Description STATUS Matrix status OK UPDATING DISCONNECT or ERROR Returned if the matrix is OK updating from a remote router for...

Page 36: ...ssigned No Change Note that future protocol versions may support more than 10 presets and therefore may return information for more or less than 10 presets for the psetData and psetNames arrays 3 11 1...

Page 37: ...P address of the system and is used for IP communications over the Ethernet network This setting is saved and recalled on power up WARNING Maintaining the ability to access a device s web page and for...

Page 38: ...estination 3 on Level 2 in Preset 1 3 11 22 PairIO Command Routers only Protocol Version 2 1 NOTE Superseded by MtxGroup Command I O pairing is used for pairing destinations sources for 3D support Whe...

Page 39: ...or details NOTE Panel commands must be enabled with the PanelCmdEn Command or by setting the pnl cmdEn System Parameter to activate them Command Description PanelCmd Query all assigned panel button GP...

Page 40: ...are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left button as button 1 followed by number 2 in the lower left corner number 3 in the top seco...

Page 41: ...ton 1 The third command assigns the condition P1 to GPIO pin 4 ID 68 The fourth command clears the condition assigned to GPIO pin 4 3 11 26 PanelDis Command Protocol Version 2 4 Query or assign intern...

Page 42: ...nd recalled on system power up The default refresh rate is 5 seconds This value is stored and recalled on power up Command Description PanelRate Query current panel refresh rate in seconds PanelRate R...

Page 43: ...the protocol used on the serial port the only valid value is currently Mascot Examples ProtoSer Mascot 3 11 31 PsetNames Command Routers and MSC GCP2U32 only Query or assign preset names Preset names...

Page 44: ...DEST LEVEL in PRESET Example PSub 1 2 PSub 1 3 2 The first command removes any connection to Destination 2 in Preset 1 The second command removes any connection to Destination 3 Level 2 on Preset 1 3...

Page 45: ...e or disable reclockers 0 or 1 respectively Examples ReclkDis 0 ReclkDis 1 The first command above queries the current reclocker disable value which returns 0 the default reclockers enabled The second...

Page 46: ...Lvl1 DestNLvl2 SrcLvl2 Example S1 Dest1 Src4 Dest1 Src4 Dest2 Src3 Dest2 Src3 Dest3 Src2 Dest3 Src2 Dest4 Src1 Dest4 Src4 The example above is output from a two level Video and Audio for example 4x4 m...

Page 47: ...f listing all writable parameters and setting the net ip parameter Set ctl serial baud ctl serial log ctl serial proto ctl serial2 baud ctl serial2 log ctl serial2 proto dbg i2cAckFails dbg i2cArbLoss...

Page 48: ...s Stored value 3 11 42 SrcNames Command Routers and MSC GCP2U32 only Query or assign source names This command has 4 variations described by the following table Source names are stored and recalled o...

Page 49: ...and assigning system name SysName MSC Router SysName MyRouter 3 11 44 SysType Command Protocol Version 2 3 NOTE Superseded by the sys arch System Parameter Query the system series type which is curre...

Page 50: ...ration parameters Note that variables consisting of JSON data simply show the string JSON to keep the output concise The output consists of one line per variable with the variable name followed by an...

Page 51: ...11 48 X Command Routers and MSC GCP2U32 only Query or make changes to the matrix routing state This command comes in several variations described by the following table Command Description X Query com...

Page 52: ...stination 3 on all levels and the fourth command mutes destination 4 level 2 Command stacking Command stacking is especially useful for the X command since it allows for several connections to be perf...

Page 53: ...image has been transferred to the device s FLASH storage area 5 The device will automatically reboot to perform the remainder of the software update during which the web page interface may display a...

Page 54: ...to the IP address 192 168 2 59 Consult the TFTP Software section for details 4 3 TFTP Software There are many different options for TFTP client programs the choice of which depends on what operating s...

Page 55: ...put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer...

Page 56: ...TFTP transfer binary put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initi...

Page 57: ...unning A computer system can then be configured with an IP address on the same IP subnet and the webpage configuration can be loaded for viewing and changing the IP address as described in the section...

Page 58: ...90 Non Condensing Warranty 2 Years Parts Labor SDI Video Connector type BNC Data Types SMPTE 259M 292M 424M Data Rates 19 Mbit s through 3 0 Gbit s Re clocking Data Rates 270 Mbit s 1 485 Gbit s 2 97...

Page 59: ...erminated by default for use as an endpoint of 2 or more RS 485 connected devices Pin Name Function 1 4 6 7 NC Not Connected 2 TX RS 232 Transmit 3 RX RS 232 Receive 8 D RS 485 Data Positive 9 D RS 48...

Page 60: ...means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled zero or more...

Page 61: ...hich shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH A...