background image

MSC-DE4832 Product Manual

Command

Description

PanelExtEn

Query external panel interface enable setting.

PanelExtEn 0 | 1

Assign external panel interface enable setting (0: disable, 0: enable)

Examples

>PanelExtEn

0

>PanelExtEn 1

>

The first command queries the current external panel interface setting (0: disabled).  The second command 
enables the external panel interface.

3.11.29 PanelRate Command

Protocol Version: 2.1

For changing remote button panel refresh rate.  When a button panel is configured to control a remote router the
current connection status is refreshed at regular intervals.  This command can be used to increase or decrease 
the rate, which is saved and recalled on system power up.  The default refresh rate is 5 seconds.  This value is 
stored and recalled on power up.

Command

Description

PanelRate

Query current panel refresh rate (in seconds).

PanelRate RATE

Set remote panel refresh rate in seconds.

Examples

>PanelRate

5

>PanelRate 1

>

The first command queries the current panel refresh rate, which returns 5 (default).  The second command sets 
the refresh rate to be 1 second.

3.11.30 PClr Command

Routers and MSC-GCP2U32 only

Clear a preset.  For Preset 0 this sets all Destinations to Source 0.  Other Presets are assigned “No Change” to 
all Destinations.  This command stores preset information which is available through system power cycles.

Command

Description

PClr PRESET

Clear a preset.

Example to clear preset 1

Page 41 of 60

© 2013-2019 Matrix Switch Corporation

www.matrixswitch

 

 corp.com

 

 

Summary of Contents for MSC-DE4832

Page 1: ...Matrix Switch Corporation MSC DE4832 Product Manual 2RU 48 input 32 output AES Audio Router Revision 1 8 Page 1 of 60 2013 2019 Matrix Switch Corporation www matrixswitchcorp com ...

Page 2: ...ALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life support and or safety applications is entirely at the buyer s risk and the buyer agrees to defend indemnify and hold harmless Matrix Switch Corporation from any and all damages claims suits or expenses ...

Page 3: ... commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Added MSC CP59X59E panel Revision 1 2 2015 08 20 Added protocol commands MtxGroup PanelDis and PanelExtEn Updated Mascot protocol information to version 2 4 New manuals for MSC V1616 LS DC MSC 1HD1616 L...

Page 4: ...14 2 3 2 Saving Work Matrix to a target 14 2 3 3 Usage scenarios 14 2 4 Labels Tab 14 2 5 Config Tab 15 2 5 1 System Settings 16 2 5 2 Network Settings 16 2 5 3 Button Panel Settings 17 2 6 Command Tab 18 3 Mascot Control Protocol 19 3 1 Protocol Changes 19 3 2 Telnet Access 20 3 3 Serial Access 20 3 4 Command Format 20 3 4 1 Command Names 21 3 5 Response Format 21 3 6 Command Arguments 22 3 7 Sys...

Page 5: ...Cmd Command 38 3 11 25 PanelCmdEn Command 39 3 11 26 PanelCond Command 39 3 11 27 PanelDis Command 40 3 11 28 PanelExtEn Command 40 3 11 29 PanelRate Command 41 3 11 30 PClr Command 41 3 11 31 ProtoSer Command 42 3 11 32 PsetNames Command 42 3 11 33 PSub Command 43 3 11 34 PView Command 43 3 11 35 Reboot Command 44 3 11 36 ReclkDis Command 44 3 11 37 RemoteSync Command 44 3 11 38 S Command 45 3 11...

Page 6: ...e recovery procedure 54 4 3 TFTP Software 54 4 3 1 Windows 54 4 3 2 Mac OS X 55 4 3 3 Linux 55 5 Troubleshooting 57 5 1 Unknown IP address 57 5 2 No Ethernet link when connected to network switch 57 5 3 Unexpected reboots 57 6 Reference 58 6 1 Specifications 58 6 2 Serial Interface Pinout 58 6 3 Glossary 59 7 Matrix Switch Corporation Warranty 60 Page 6 of 60 2013 2019 Matrix Switch Corporation ww...

Page 7: ... be left unconnected External Audio Router Optional An additional Matrix Switch Corporation AES or analog audio router can be utilized with this router by connecting it to the AFV connector with a 25 pin straight through cable NOTE The audio router should be powered on before the primary router to ensure proper initial routing state or alternatively Preset 0 can be recalled to initialize it at any...

Page 8: ... 255 255 0 A Gateway address is not necessary for this purpose but could be set to 192 168 2 1 3 Make sure the device is powered on 4 Using a web browser on the computer enter the device s IP address into the Location bar and press ENTER The device web page interface should load If the web page interface fails to load double check the computer s network settings and physical Ethernet connections I...

Page 9: ...n applications with a single router and optionally one remote panel on the same Ethernet network Larger installations or integration with existing IP LAN networks require some network planning NOTE Matrix Switch Corporation can assist in planning and pre configuring devices for specific application requirements at purchase time Just ask a sales or customer service representative Manual IP address ...

Page 10: ...n remote panels which will be accessing routers across network subnets but this setting is otherwise not needed After assigning device network settings including unique IP addresses remote panels need to be assigned the correct IP addresses to their Remote Router IP setting of the router they will control Additional configuration changes may be required depending on the application and are describ...

Page 11: ...nstallation example consisting of a 32x32 SDI Video Router with a secondary level 32x32 Analog Audio router connected via the AFV DB 25 interface a 32x32 Remote Button Panel a 2RU LCD Remote Panel and a Computer system Page 11 of 60 2013 2019 Matrix Switch Corporation www matrixswitchcorp com ...

Page 12: ...lines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 System name can be assigned on the Config tab 2 System firmware series and version 3 Tab navigation 4 Preset load drop down selection 5 Source connect buttons 6 Mute button may not be available on all sw...

Page 13: ...e Destination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the Load preset drop down selector 4 in Figure 1 and selecting the desired preset which is then loaded and applied to the current routing matrix More information on Presets is contained in the following Pr...

Page 14: ...o a Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab interface allows for several useful scenarios some of which are described below Batch connection operations To perform several connection operations all at the same time make the desired connection...

Page 15: ...umns for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to use the same label as the first level Presets can also be assigned label names Click the Save button to save changes that have been made 2 5 Config Tab Page 15 of 60 2013 2019 Matrix Switch Corporatio...

Page 16: ...characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all Routers 3D I O Pairing Enable pairing of destinations sources for two channel 3D support only supported by Routers with 2 or more destinations 2 5 2 Network Settings WARNING DHCP should only be enabled or the IPAddress or Netmask c...

Page 17: ...e panels control different levels of a Video Audio Router Control Mode Set the matrix control mode only present on Routers Available options include Local Button panel controls the router itself Remote Button panel controls a remote router at the IP address set by the Remote Router IP field Remote Sync Synchronize matrix crosspoint changes to another router at the IP address specified by the Remot...

Page 18: ...e Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all command output in the lower area See the section Mascot Control Protocol for more information Page 18 of 60 2013 2019 Matrix Switch Corporation www matrixswitchcorp com ...

Page 19: ...control system manufacturers who support MASCOT contact Matrix Switch Corporation 3 1 Protocol Changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot version 3 0 Added System Parameter commands Get GetS Set SetA and SetS commands Current system parameters ...

Page 20: ... prompt character 3 3 Serial Access Matrix Switch router systems come equipped with a serial port which can be used as another means of sending Mascot commands Connect a Computer system to the device using a 9 pin RS 232 serial cable Using this interface requires a serial terminal program such as HyperTerminal on Windows Configure the terminal software for 9600 bps 8N1 In addition Local Echo shoul...

Page 21: ...cters ASCII 13 followed by ASCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive additional commands If an error occurs in response to a command an error will be displayed prior to the prompt with the following format E00 Error message 00 will contain a 2 digit decimal error code Table 4 shows possible error codes w...

Page 22: ...hesis Arg Square brackets indicate an optional argument and parenthesis indicate a required argument Any optional argument specified requires that all prior optional arguments are also specified Table 6 lists currently used command argument types Argument Valid Range Meaning Boolean 0 1 T F True False Boolean true or false value Cmd String MASCOT command Cond String Condition statement See PanelCo...

Page 23: ...arameter values Set Parameter Value Set Active Stored parameter value depends on parameter SetA Parameter Value Set Active value of a parameter only SetS Parameter Value Set Stored value of a parameter only Table 7 System Parameter Commands Parameter identifiers are represented as one or more alphanumeric words separated by periods representing a tree structure similar to file folders or directori...

Page 24: ...terface mask pnl cmdEn Boolean RW AS Panel command macro enable pnl ip IP RW AS Remote IP address for panel interface to control sys arch String R System architecture Pyxis Carina Lynx etc sys firmware String R Firmware series and version Pyxis 1 1 7 for example sys name String RW AS System name identifier 3 8 Core Commands This section outlines commands considered to be core MASCOT protocol comma...

Page 25: ... 1 Enable panel button GPIO command macros PanelCond Button Cond Panel button GPIO status conditions PanelDis 0 1 Internal panel button interface disable PanelExtEn 0 1 External panel interface enable if available PanelOfs Dest Src Lvl Lvl Button panel destination source offsets and levels to control PanelRate Number Remote panel refresh rate SerBaud Number Query or assign serial baud rate SysName...

Page 26: ...f system destinations Srcs is the count of sources and Levels is the number of system levels The Flags1 and Flags2 fields are currently unused and will be 0 Example for a 16x16 system with 2 levels C 16 16 2 0 0 3 11 3 DestNames Command Routers and MSC GCP2U32 only Query or assign destination names This command has 4 variations described by the following table Destination names are saved and recal...

Page 27: ...y Using DHCP allows for dynamic IP or fixed IP assignment from a central location the DHCP server Using this option is only recommended if using fixed IP assignment by MAC address or if there is a way to determine what IPs the Matrix Switch Corporation systems get assigned Otherwise it may become difficult to determine what IP address to use when accessing the Web Page or other control interfaces ...

Page 28: ...m firmware series and version Example Firmware Pyxis 1 1 7 3 11 7 FrameIP Command NOTE Superseded by the pnl ip System Parameter Query or assign the remote router IP address Usually only used on Remote Panel devices or in conjunction with the RemoteSync Command to create a dual router 3D system Sets the IP address of the Router system which the button panel will connect to and control or which the...

Page 29: ...ommand queries Active values of parameters which may differ from values in Stored memory Values in Stored memory are loaded at system startup and can be queried with the GetS Command See System Parameters for more details Command Description Get Display all system parameter Active values Output consists of one parameter per line with the parameter identifier separated by an equals character and th...

Page 30: ...lue of a single parameter or a subset of parameters under a given parameter node 3 11 11 Help Command Display command reference information 3 11 12 IP Command NOTE Superseded by the net ip System Parameter Query or assign the system IP address This setting is saved and recalled on power up WARNING Maintaining the ability to access a device s web page and for Remote Panel devices to be able to comm...

Page 31: ...ed by the net mac System Parameter Query system Ethernet MAC address Command Description MAC System Ethernet MAC address in hh hh hh hh hh hh where each hh is a pair of hex digits Example MAC 00 50 C2 8B DF FE 3 11 15 MapDest Command Routers only Protocol version 3 0 Query or assign matrix destination mappings Destination mappings provide a means to remap logical destinations to different physical...

Page 32: ...destination 5 on all levels The fourth example maps destination 1 to physical destination 6 on the second level only 3 11 16 MapSrc Command Routers only Protocol version 3 0 Query or assign matrix source mappings Source mappings provide a means to remap logical sources to different physical sources for an added level of convenience when allocating and defining system I Os Command Description MapSr...

Page 33: ...umbers separated by a period such as 2 3 Example MascotVer 2 3 3 11 18 MtxCfg Command Routers and MSC GCP2U32 only Protocol Version 2 0 Query matrix configuration This command replaces the C command and provides the ability to query the matrix dimensions labels current matrix state and preset data The information to return is specified by the sum of the flags values listed in the following table F...

Page 34: ... name NAME type TYPE destCount DEST_COUNT srcCount SRC_COUNT flags FLAGS destNames NAME NAME srcNames NAME NAME state SRC SRC psetData SRC SRC psetNames NAME NAME Table of information on values in capital letters above Label Description STATUS Matrix status OK UPDATING DISCONNECT or ERROR Returned if the matrix is OK updating from a remote router for example one or more remote routers disconnected...

Page 35: ...9 The example output above is a typical response for a 4x4 Video router Current matrix routing is straight through 10 presets are defined 1st is straight through 2nd is mapped all to source 1 and all other presets have not been assigned No Change Note that future protocol versions may support more than 10 presets and therefore may return information for more or less than 10 presets for the psetDat...

Page 36: ...two level router this would result in an 8x8 matrix on level 1 and a 4x4 matrix on level 2 3 11 20 NetMask Command NOTE Superseded by the net netmask System Parameter Query or assign the system network mask value This value is related to the IP address of the system and is used for IP communications over the Ethernet network This setting is saved and recalled on power up WARNING Maintaining the ab...

Page 37: ... 1 3 0 2 The first command adds a connection from Source 3 to Destination 2 in Preset 1 The second command Mutes Destination 3 on Level 2 in Preset 1 3 11 23 PairIO Command Routers only Protocol Version 2 1 NOTE Superseded by MtxGroup Command I O pairing is used for pairing destinations sources for 3D support When activated a router will appear to have half the number of physical destinations and ...

Page 38: ...or GPIO pin 1 NOTE Panel commands must be enabled with the PanelCmdEn Command or by setting the pnl cmdEn System Parameter to activate them Command Description PanelCmd Query all assigned panel button GPIO commands PanelCmd Button Query a single panel button GPIO command PanelCmd Button Command Assign a panel button GPIO command Assigning a blank command to a button or GPIO pin will clear the comm...

Page 39: ...el buttons and GPIO pins are specified by numeric ID Panel buttons are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left button as button 1 followed by number 2 in the lower left corner number 3 in the top second column continuing to alternate between top and bottom rows till the last button lower right hand corner NOTE Condition statements ...

Page 40: ...mmand queries the panel condition for button 1 The third command assigns the condition P1 to GPIO pin 4 ID 68 The fourth command clears the condition assigned to GPIO pin 4 3 11 27 PanelDis Command Protocol Version 2 4 Query or assign internal button interface panel disable setting This setting is stored and recalled on power up Command Description PanelDis Query internal panel disable setting Pan...

Page 41: ...ich is saved and recalled on system power up The default refresh rate is 5 seconds This value is stored and recalled on power up Command Description PanelRate Query current panel refresh rate in seconds PanelRate RATE Set remote panel refresh rate in seconds Examples PanelRate 5 PanelRate 1 The first command queries the current panel refresh rate which returns 5 default The second command sets the...

Page 42: ...O Assign the protocol used on the serial port the only valid value is currently Mascot Examples ProtoSer Mascot 3 11 32 PsetNames Command Routers and MSC GCP2U32 only Query or assign preset names Preset names are stored and recalled on power up Command Description PsetNames Query all preset names PsetNames PRESET Query a single preset name PsetNames PRESET LABEL Assign a preset label When querying...

Page 43: ...n to DEST LEVEL in PRESET Example PSub 1 2 PSub 1 3 2 The first command removes any connection to Destination 2 in Preset 1 The second command removes any connection to Destination 3 Level 2 on Preset 1 3 11 34 PView Command Routers and MSC GCP2U32 only View presets Displays the content of one or all presets The format of the returned output is 1 S1 S2 2 S1 S2 where the 1 and 2 are incrementing de...

Page 44: ... Enable or disable reclockers 0 or 1 respectively Examples ReclkDis 0 ReclkDis 1 The first command above queries the current reclocker disable value which returns 0 the default reclockers enabled The second command disables the reclockers 3 11 37 RemoteSync Command Routers only Protocol Version 2 1 Command to enable syncing matrices of two router systems Usually used for creating a 3D matrix from ...

Page 45: ...l1 SrcLvl1 DestNLvl2 SrcLvl2 Example S1 Dest1 Src4 Dest1 Src4 Dest2 Src3 Dest2 Src3 Dest3 Src2 Dest3 Src2 Dest4 Src1 Dest4 Src4 The example above is output from a two level Video and Audio for example 4x4 matrix with sources routed in reverse order except destination 4 which has a 2nd level break away which is routed from source 4 3 11 39 SerBaud Command NOTE Superseded by the ctl serial baud and ...

Page 46: ...of listing all writable parameters and setting the net ip parameter Set ctl serial baud ctl serial log ctl serial proto ctl serial2 baud ctl serial2 log ctl serial2 proto dbg i2cAckFails dbg i2cArbLosses dbg i2cBusErrors dbg i2cOverruns dbg i2cTimeouts dbg i2cResets mtx sync net dhcp net gateway net ip net mac net netmask pnl cmdEn pnl ip sys descr sys name sys type Set net ip 192 168 2 60 3 11 41...

Page 47: ...r s Stored value 3 11 43 SrcNames Command Routers and MSC GCP2U32 only Query or assign source names This command has 4 variations described by the following table Source names are stored and recalled on power up Command Description SrcNames Query all source names SrcNames SRC Query source names for all levels of a given source SrcNames SRC LEVEL Query the name of a specific source and level SrcNam...

Page 48: ... and assigning system name SysName MSC Router SysName MyRouter 3 11 45 SysType Command Protocol Version 2 3 NOTE Superseded by the sys arch System Parameter Query the system series type which is currently defined as one of the following values Value Series name 0 Carina 1 Lupus 2 Lynx 3 Hydra 4 Pyxis NOTE This command was not added until version 2 3 of the Mascot protocol On previous versions this...

Page 49: ...uration parameters Note that variables consisting of JSON data simply show the string JSON to keep the output concise The output consists of one line per variable with the variable name followed by an equals and then the value not quoted Examples Vars DefaultProfile 1 DHCP 1 DNSPri 0 0 0 0 DNSSec 0 0 0 0 Firmware 1 5 1 Gateway 192 168 2 1 IP 192 168 2 80 Mac 00 00 00 00 00 00 MascotVer 2 MtxProfil...

Page 50: ...11 49 X Command Routers and MSC GCP2U32 only Query or make changes to the matrix routing state This command comes in several variations described by the following table Command Description X Query complete routing state equivalent to S Command X DEST Query connected sources for DEST for all levels X DEST SRC Connect SRC to DEST for all levels X DEST SRC LEVEL Connect SRC to DEST LEVEL When queryin...

Page 51: ...estination 3 on all levels and the fourth command mutes destination 4 level 2 Command stacking Command stacking is especially useful for the X command since it allows for several connections to be performed at the same time Example X1 4 X2 3 X3 2 X4 1 The above would connect source 4 to destination 1 source 3 to destination 2 source 2 to destination 3 and source 1 to destination 4 for all levels P...

Page 52: ...a fixed update IP address of 192 168 2 59 whereas CSU uses the device s configured IP address POSU should be available even if a device s firmware gets corrupted from a previous update attempt whereas CSU will likely no longer be possible POSU has a shorter TFTP update time window of 5 seconds and the TFTP transfer has to occur within this period after power cycling the device This means the PC ne...

Page 53: ...is an Ethernet switch between the device and update PC Steps for executing a Command Software Update 1 Ensure that the Software Update Requirements are met 2 Configure the PC for a unique IP address on the same IP network as the device if not already Make sure that there are no IP conflicts with the PC or device 3 Prepare the TFTP program to transfer the firmware file to the device but do not init...

Page 54: ...ng order If network communication with the device is not working ensure network cabling and interconnect hardware is functioning ensure the proper IP address is being used to connect to the device is unique on the network and that the system being used to connect to the device has a unique IP on the same network subnet Consult the Unknown IP address section for details on recovering from an unknow...

Page 55: ...application for example your home directory at Users your_user_name 2 Open a terminal Applications Utility Terminal 3 Use cd commands to change to the location of the firmware file for example cd Users your_user_name followed by the ENTER key 4 Execute the tftp command with the IP address of the device make sure to use the device s configured IP if the update method being used utilizes the devices...

Page 56: ... the device make sure to use the device s configured IP if the update method being used utilizes the devices IP address tftp 192 168 2 59 5 Execute the following commands from within the tftp program pressing ENTER after each line except the last one to prepare the TFTP transfer binary put MSC Carina Firmware x x x hex 6 Make sure to replace MSC Carina Firmware x x x hex with the correct version n...

Page 57: ...terminal application once connected and a prompt character should be displayed Type the following commands pressing ENTER after each one to get the IP address and netmask ip netmask 5 2 No Ethernet link when connected to network switch This device utilizes a 10 BaseT Ethernet interface In the event that the device is connected to a network switch and no physical link is established please try the ...

Page 58: ...2 lbs Power 12 VDC 5 Amp Power Connector DE 9 Male Storage Temp 10 Through 100 Deg C Operating Temp 0 Through 75 Deg C Humidity 0 Through 90 Non Condensing Warranty 2 Years Parts Labor Control Specifications Serial RS232 9600 bps 8N1 Ethernet 10 BaseT Local Panel Interface Remote Panel Support Yes Digital Audio Connector Type BNC Input level 200mV to 5V P P Input impedance 75 Ohm 1 Output level 1V...

Page 59: ... to Matrix Switch Corporation devices Matrix Used when referring to a Router s entire routing state Mute When supported a destination can be muted which for video means the output is turned off and for audio means it is silenced Output Synonymous with Destination Preset Matrix Switch Corporation Router devices provide 10 presets which store matrix Routing connections When a preset is recalled zero...

Page 60: ...which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH ABOVE NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MSC EXPRESSLY DISCLAIMS ALL EXPRESS OR IMP...