MSC-1HD0816L Product Manual
This device is not equipped with a power switch and is simply connected to the power supply adapter which is
plugged into a suitable AC power source, to power it up.
Once the device is powered it goes through the following startup sequence:
•
5 second startup delay to allow for
•
Routing matrix is initialized to Preset 0 state (defaults to source 1 connected to all destinations).
•
The button control panel is initialized and buttons are illuminated to show the initial routing status.
1.3 Front Panel Button Interface
The MSC-1HD0816L is equipped with a 16x16 button panel which provides one of several options for
controlling and viewing the status of the routing matrix.
This panel interface provides separate input and output buttons. One output button is active at a time, indicated
by it being lit. The current connection status for the active output is indicated by the relevant numbered input
button being lit. Pressing an input button will cause that input to be connected to the current active output.
1.3.1 Audio Breakaway
An audio breakaway is performed by first selecting the desired output, by pressing the relevant output button,
then pressing and
holding
an input button, followed by pressing another input button. The 1st input button
pressed selects the source of the primary level. The 2nd input button pressed will become the secondary (audio)
source and will flash, indicating a breakaway.
1.4 Web Page Interface
All Matrix Switch Corporation router and panel devices come with a built-in web page interface.
This is the recommended interface for configuration and is also a convenient way to control the matrix routing
of the device.
Devices come factory configured with default settings, unless a pre-configuration request is made during
purchase, an example being a multi device application.
1.4.1 Accessing The Web Page Interface
The default network IP address for this device is 192.168.2.60. Refer to the table below for the default IP
addresses for other types of Matrix Switch Corporation devices.
Device Type
Default IP Address
Video/Audio Routers
192.168.2.60
Remote Button Panels
192.168.2.64
Remote LCD Screen Panels
192.168.2.80
Table 2: Default System IP Addresses
To access the web page interface of the device:
1. Connect the Ethernet port of a computer either directly to the device using a crossover cable to the same
Page 8 of 60