64
Command Summary
7.1
Optical Characteristics
Table 72: Display Optics
Module Size
138.00 x 38.00 x 26.91
mm
Viewing Area
98.0 x 28.4
mm
Active Area
93.57 x 24.93
mm
Pixel Size
0.36 x 0.36
mm
Pixel Pitch
0.39 x 0.39
mm
Viewing Direction
12
O’clock
Viewing Angle
-30 to +30
°
Contrast Ratio
3
Backlight Half-Life
20,000
Hours
*Note:
Backlight half-life is rated for normal operating conditions only: 25±10°C and 45±20% Relative Humidity.
8
Ordering
8.1
Part Numbering Scheme
Table 73: Part Numbering Scheme
GLK -24064R -25 -1U -USB -FGW
-E
1
2
3
4
5
6
7
8
8.2
Options
Table 74: Display Options
#
Designator
Options
1
Product Type
GLK: Graphic Liquid Crystal Display with Keypad Input
GLT: Graphic Liquid Crystal Display with Touchpad Input
2
Display Size
24064R: 240 pixel columns by 64 rows, R screen size
3
Keypad Size
*
NP: No keypad
25: 25 key maximum
4
Form Factor
1U: Designed to 1U, or PC bay insert, dimensions
5
Protocol
*
NP: Standard Model
-USB: USB Only Model
-422: RS422 Only Model
**
6
Colour
*
NP: Black Text with Yellow-Green Background
FGW: Black Text with Grey-White Background
WB: White Text with Blue Background
TCI: Tricolour Text with Black Background
7
Voltage
*
NP: Standard Voltage
-VPT: Wide Voltage with Efficient Switching Power Supply
8
Temperature
*
NP: Standard
***
-E: Extended Temperature
*Note:
NP means No Populate; skip this designator in the part number and move to the next option.
**Note:
The RS422 model should only be powered from a local source, unless the –VPT variant is used.
***Note:
Extended Temperature is available for keypad input units only; -E is not available for GLT models.