background image

 

 

 

 

II. LIMITED WARRANTY 
 

This equipment is sold by MATHESON under the warranties set forth in the following 
paragraphs.    Such warranties are extended only with respect to the purchase of this 
equipment directly from MATHESON or MATHESON's Authorized Agent as new 
merchandise and are extended to the first Buyer thereof other for than the purpose of 
resale. 
 
For a period of one year from date of original delivery (ninety days in corrosive service) 
to Buyer or to Buyer's order, this equipment, is warranted to be free from functional 
defects in materials and workmanship and to conform to the description of this equipment 
contained in this manual and any accompanying labels and/or inserts, provided that this 
equipment is properly operated under the conditions of normal use and that regular and 
periodic maintenance and service is performed or replacements are made in accordance 
with the instructions provided.    Expendable parts of this equipment are similarly 
warranted to be free from functional defects in materials and workmanship and to 
conform to the description of this equipment contained in this manual and any 
accompanying labels and/or inserts.    The foregoing warranties shall not apply if the 
equipment has been repaired other than by MATHESON or a service facility designated 
by MATHESON, or if this equipment has not been operated and maintained in 
accordance with written instructions provided by MATHESON, or has been altered by 
anyone other than MATHESON, or if the equipment has been subject to abuse, misuse, 
negligence or accident. 
 
MATHESON's sole and exclusive obligation and the Buyer's sole and exclusive remedy 
under the above warranties is limited to repairing or replacing, free of charge, at 
MATHESON's sole discretion, the equipment or part which is telephonically reported to 
be a problem to the local MATHESON Branch Location, and which if so advised, is 
returned with a written statement of the observed deficiency, not later than seven days 
after the expiration of the applicable warranty, to the MATHESON Gas Equipment 
Technology Center during normal business hours, transportation charges prepaid, and 
which, upon examination, is found to comply with the above warranties.    The Buyer 
shall pay for return trip transportation charges for the equipment or part. 
 

MATHESON shall not be otherwise liable for any damages including but not 
limited to incidental damages, consequential damages, or special damages, whether 
such damages result from negligence, breach of warranty or otherwise. 
 
There are no express or implied warranties that extend beyond the warranties 
hereinabove set forth.    MATHESON makes no warranty of merchantability or 
fitness for a particular purpose with respect to the equipment or parts thereof.

   

 

 

Acceptance of the equipment by the final buyer 

indicates the final buyer’s 

acceptance of all warranties and limitations set forth above. 

 

 

Summary of Contents for PUR-Gas MCTG-0050

Page 1: ...MINT 0248 rev B PUR Gas Purifier System Instructions READ AND COMPLY WITH THESE INSTRUCTIONS BEFORE INSTALLING OPERATING OR SERVICING ...

Page 2: ......

Page 3: ...R RESPONSIBILITY 3 IV SAFETY PRECAUTIONS 4 V GENERAL DESCRIPTION 4 VI INSTALLATION OF A BASEPLATE 5 VII STANDARD PURIFIER CARTRIDGE BASEPLATE COMBINATION 7 VIII INSTALLING A PURIFIER CARTRIDGE 8 IX REPLACEMENT OF A PURIFIER CARTRIDGE 8 X ORDERING INFORMATION 11 ...

Page 4: ......

Page 5: ...uct will be received by MATHESON without indication of gas service and without proper return material authorization provided by the warranty administrator If advised by the Warranty Administrator to return the product to MATHESON prepare the product for shipment and write in large lettering the RMA Number assigned by the Warranty Administrator on the outside of the box Also if required by the Warr...

Page 6: ...n operated and maintained in accordance with written instructions provided by MATHESON or has been altered by anyone other than MATHESON or if the equipment has been subject to abuse misuse negligence or accident MATHESON s sole and exclusive obligation and the Buyer s sole and exclusive remedy under the above warranties is limited to repairing or replacing free of charge at MATHESON s sole discre...

Page 7: ...replacement become necessary MATHESON recommends that a telephonic or written request for service advice be made to the MATHESON Equipment Engineering Group in Montgomeryville Pennsylvania or to the nearest MATHESON branch location This equipment or any of its parts should not be altered without the prior written approval of MATHESON Equipment Engineering Group The user of this equipment shall hav...

Page 8: ...artridge check for any cracks on the inner glass tube after installation 7 NEVER REMOVE the white plastic mounting plugs located on the outside housing near the bottom of the cartridge if they are missing the cartridge should NOT be installed and should be returned to MATHESON 8 NEVER replace the baseplate fittings if new fittings are required contact MATHESON for technical assistance 9 Use only o...

Page 9: ...ate metal tubing cutter 3 Connect the gas Inlet 1 and Outlet 2 as indicated at the rear of the baseplate keeping the connections loose 4 Turn on the gas source and flush the line for at least 10 minutes with pure carrier gas at 8 psig minimum 5 Tighten the incoming gas line at the Inlet 1 rear fitting 6 Ensure that the flushcap 4 is securely tightened to the baseplate push the cap down during moun...

Page 10: ...artridge on the baseplate See SECTION VIII Installing a Purifier Cartridge for more detail 11 Flush the whole system for 15 minutes with pure carrier gas at a recommended pressure of 90 psig 12 Tighten the outgoing gas line at the Outlet 2 rear fitting The analytical system is now ready to be used Argon or Nitrogen peaks in the chromatogram should be negligible NOTE Always check for possible leaks...

Page 11: ...fication System for GC FID High Capacity Triple 2x Combi purifier on 3 position baseplate 2 Purification System for Fuel Gas FID 2x Combi purifier on 2 position baseplate 3 Purification System for Carrier Gas with MS ECD NPD Triple purifier on 1 position baseplate ...

Page 12: ...ed on the baseplate the Teflon seals will be punctured It is necessary to keep the purifier cartridge in position to prevent air from entering the system 2 Regularly check both the big and small Viton O rings on the baseplate for hair cracks The slightest leak allows moisture oxygen and hydrocarbons to enter the system and contaminate the gas 3 All MATHESON PUR Gas purifier cartridges are packed u...

Page 13: ... Cartridge Label 1 Type of purifier cartridge 2 MATHESON part number for purifier cartridge 3 Indicator color before saturation 4 Indicator color after saturation 5 Installation date to be filled in by user 6 Month Year of production 1 2 4 5 6 3 ...

Page 14: ...en 1000 Hydrocarbon Not specified Combi 3 6 Not specified Triple 1 8 500 Not specified Note The data given in the table strongly depends on the level of gas purity prior to entering the purifier Note Replacement of the purifier cartridge is recommended at least every six months regardless of the saturation level ...

Page 15: ...sition Baseplate with 1 4 SS Fittings MBAS 0027 2 Position Baseplate with 1 4 SS Fittings MBAS 0028 3 Position Baseplate with 1 4 SS Fittings MBAS 0029 2 Position LC MS Baseplate with 1 4 SS Fittings MCTG 0050 Moisture Cartridge MCTG 0051 Oxygen Cartridge MCTG 0052 Hydrocarbon Cartridge MCTG 0053 Triple Cartridge O2 H2O HC MCTG 0054 Combi Cartridge H2O HC MCTG 0055 LC MS Charcoal Cartridge Set 2 M...

Page 16: ...nc cannot guarantee the accuracy of this material nor can it accept responsibility for errors or omissions This document is intended to serve as a general orientation and cannot be relied upon for a specific operation No warranties of any nature are extended by the information contained in these copyrighted materials All names products and services mentioned herein are the trademarks or registered...

Reviews: