Matelec FSA-60000 Quick Start Manual Download Page 1

M A T E L E C   A U S T R A L I A .   P   1 8 0 0   2 8 1   2 8 2 .   F   1 3 0 0   2 8 1   2 8 2

I N F O @ M A T E L E C A U S T R A L I A . C O M . A U .   W W W . M A T E L E C A U S T R A L I A . C O M . A U

•  This product must only be used for the purpose described in these instructions and must be installed in  
 

accordance with local wiring rules and regulations.

Main Power Source

220-240 V AC/50 Hz

Secondary Power Source

DC 3V battery: CR17450

AC Operating Current

<100mA

Interconnecting

Max. 24 alarms (wired 150m maximum)

Operating Temperature

0 °C to 40 °C

Ambient Humidity

≤ 93%

Alarm Sensitivity

0.118-0.169 dB/m

Alarm Volume

≥ 85dB(A) @ 3m

Sound Pattern

ISO8201(BI 0.5s - pause 0.5s- BI 0.5s - pause 

0.5s - BI 0.5s - pause 1.5s, with the RED LED 

flashing, repeat this alarm pattern)

Complies with

AS3786:2014

THIS SMOKE ALARM MUST BE INSTALLED BY A LICENSED ELECTRICIAN IN ACCORDANCE 

WITH AUSTRALIAN WIRING RULES

  

SMOKE ALARM FSA-60000

240Vac c/w 3V DC Battery Backup Photoelectric Smoke Alarm

TM

AC

TIVFIRE

    

   

D

E

T

S

I

L

Compatible

with the FSA-50000 

Wireless Interconnect

module

*Sold Separately.

Summary of Contents for FSA-60000

Page 1: ...Current 100mA Interconnecting Max 24 alarms wired 150m maximum Operating Temperature 0 C to 40 C Ambient Humidity 93 Alarm Sensitivity 0 118 0 169 dB m Alarm Volume 85dB A 3m Sound Pattern ISO8201 BI...

Page 2: ...to installation 2 As a minimum smoke alarms should be located between sleeping areas and potential sources of fire such as a kitchen heater or basement In single story homes with one sleeping area an...

Page 3: ...l mounting plugs See Diagram A 5 Follow wiring details as per Diagram D 6 Attach the base to the mounting plugs and fix screws into the plugs See Diagram B 7 Close the alarm body See Diagram C MOUNTIN...

Page 4: ...seconds The buzzer fault or buzzer detection circuit fault End of life warning The unit chirps between the Red LED flashing twice The unit will send end of life warn ing after 10 years of operation A...

Page 5: ...smoke alarm Take out the battery and turn off the AC power Wait 3 minutes then install battery and turn on the AC power Self test fault warning Press the TEST button at least 15s then release False al...

Page 6: ...the red LED will extinguish after 8 seconds and unit will beep 3 times in quick succession The red LED will then flash twice quickly every 8 seconds This indicates that while the module has been recog...

Page 7: ...5 A fire drill at least every six months including drills at nights Practice allows you to test your plan before an emergency You may not be able to reach your children It is important that they know...