Matelec FPC-30000 Owner'S Operation Manual Download Page 2

INSTALLATION 

 

3

Mounting
Connection

WELCOME TO DUAL PUMP CONTROL

Your Dual Pump Controller reflects the superior quality and attention to detail in 
design, engineering and manufacturing that has distinguished MATelec Products for 
decades. The controller incorporates the very latest in micro-processor technology, 
ensuring you, the owner/operator, of many years of functional, reliable and ‘user 
friendly’ operation.

Please read this manual prior to installation and operation of the controller.

GETTING STARTED   

4

Operations
Features

WARNING:

 

All electrical connections must be carried out by a suitably 

qualified and registered electrician.

•  Prior to Installation, ensure power supply is isolated.
•  Power supply must be Circuit Breaker Protected. (Qualified Electrician to determine appropriate amp 
   rating.)
•  Electrical connection to the panel must be carried out in accordance with ‘Connection Instructions’, 
   see page 3.
•  Additions or modifications to the control panel are not permitted and will void warranty.
•  The controller is not intended for use by children or infirm persons without supervision.
•  Repairs to the Controller must only be carried out by a suitably qualified Electrician.

2

SAFETY 

 

 

2

CIRCUIT DIAGRAM   

7

AT A GLANCE   

 

8

Indicators
Push Buttons

CONTENTS

SAFETY

Summary of Contents for FPC-30000

Page 1: ...U A L P U M P C O N T R O L L E R AUTO OFF AUTO OFF MAN MAN MUTE RESET PUMP ON PUMP ON FAULT FAULT LEVEL ALARM POWER ON Steady Overload Flash Prime Loss Steady Overload Flash Prime Loss Press and hol...

Page 2: ...WARNING All electrical connections must be carried out by a suitably qualified and registered electrician Prior to Installation ensure power supply is isolated Power supply must be Circuit Breaker Pr...

Page 3: ...EL F SET THERMAL OVERLOADS TO SUIT PUMP 1 Controller enclosure must be mounted in a vertical position 2 Ensure mounting method does not compromise enclosure weather proof rating 3 Ensure access to mai...

Page 4: ...vel input must be closed for Pump Start and Pump Stop inputs to function The High Level input however will still override the Low Level and run both pumps Input functions are as follows Position Off O...

Page 5: ...to obviate pump chatter Upon Input 1 contact closure the pump will not start delay start for 1 second and will not stop minimum run time for 10 seconds or 11 sec onds from close of Input contacts This...

Page 6: ...Alarm Delay Typically used for Storm Water applications High Level Alarm delay in this mode is 15 minutes Setting this DIP Switch to On will cause the High level Alarm to remain active until the contr...

Page 7: ...TPUT 10amp CONTROL CIRCUIT BREAKER ISOLATOR SWITCH STROBE BUZZER TRANSFORMER 12Vac 240Vac INPUT 1 SWITCH INPUT 2 SWITCH INPUT 3 SWITCH INPUT 4 SWITCH 12Vdc 12Vdc P U M P 1 P U M P 2 D U A L P U M P C...

Page 8: ...C O N T R O L L E R AUTO OFF AUTO OFF MAN MAN MUTE RESET PUMP ON PUMP ON FAULT FAULT LEVEL ALARM POWER ON Steady Overload Flash Prime Loss Steady Overload Flash Prime Loss Press and hold for 3 secs to...