Matelec FPC-12724 Owner'S Operation Manual Download Page 2

WELCOME TO LIQUID LEVEL CONTROL

Congratulations on the purchase of this product.

Your  Liquid  Level  Control  product  reflects  the  superior  quality  and  attention  to  detail  in  design,  engineering  and

manufacturing that has distinguished MATelec Products for decades. The controller incorporates the very latest in

micro-processor  technology, ensuring you, the owner/operator many years of functional, reliable and ‘user friendly’ 

operation.

Please read this manual prior to installation and operation of the controller.

CONTENTS

• 

Prior to Installation, ensure power supply is isolated.

• 

Power supply must be Circuit Breaker Protected. (Qualified Electrician to determine appropriate amp rating.)

• 

Electrical connection to the panel must be carried out in accordance with ‘Connection Instructions’, see page 3.

• 

Addition or modifications to the control panel are not permitted and will void warranty.

• 

The controller is not intended for use by children or infirm persons without supervision.

• 

Repairs to the Controller must only be carried out by a suitably qualified Electrician

2

SAFETY 

  2 

NOTES 

    6

INSTALLATION   

CIRCUIT DIAGRAM   

7

Mounting   

 

 

Connection 

   

GETTING STARTED 

AT A GLANCE   

 

  8

Operations  

 

 

Indicators

Features    

 

 

Push Buttons

SAFETY

WARNING: All electrical connections must be carried out by a suitably qualified and

registered electrician

Summary of Contents for FPC-12724

Page 1: ...P U M P C O N T R O L DOC FPC 12724 VER 1 1 OWNER S OPERATION MANUAL Rain Mains Water Controller Installation and Operating Instructions MODEL FPC 12724 MAIN ISOLATOR...

Page 2: ...ly is isolated Power supply must be Circuit Breaker Protected Qualified Electrician to determine appropriate amp rating Electrical connection to the panel must be carried out in accordance with Connec...

Page 3: ...PUMP E A SUPPLY LOW LEVEL FLOAT WORKING PRESSURE SWITCH E A N INPUT SOLENOID 240Vac 12Vdc N Mounting Frame Wall MAIN ISOLATOR 1 Controller enclosure must be mounted in a vertical position 2 Ensure mo...

Page 4: ...s are energised In the event of either Rain Water Depletion Prime Loss if set up Power Failure or Pump Failure the controller will immediately pulse the valve open and de energise the pump output cont...

Page 5: ...of pump output isolates power to pressure pump system Controller can be situated up to 50m from storage tank Ideal for Industrial Commercial and or Domestic applications 5 FEATURES M A I N S WAT E R...

Page 6: ...NOTES 6...

Page 7: ...PRO BE 5 4 3 2 1 C INPUT INPUT INPUT VALVE A B C A N E E A N PUMP SUPPLY C NO AUX A1 A2 Contactor 18A 240Vac C1 L1 T1 L2 T2 L3 T3 Contactor 3P C1 240 VAC Pump P1 97 98 NO Contact TOL1 Thermal Overload...

Page 8: ...EMAIL info matelecaustralia com au MATelec reserves the right to alter technical specifications without notice Press to reset fault or momentary SYSTEM change valve state SYSTEM TEST RAIN WATER NOTE...

Reviews: