background image

1

P: 1800 281 282  

|

  F: 1300 281 282  

|

  E: [email protected]  

|

  W: www.matelecaustralia.com.au

QUICK START GUIDE

Low Level Pump Shut-Off Controller

Standard -

 FPC-11010

Introduction

MATelec Australia’s Low Level Pump Shut-Off Controller is designed to provided power supply to a pump, used to pump water from a 

tank into a home or other application. Housed in a robust polycarbonate enclosure, the controller features status indicator lights, a 

GPO for power supply to the pump and a 9006 Float Switch with quick plug connection. The controller shuts off power to the pump 

when tank is empty, preventing the pump from running dry. 

V1.1

Safety

This control panel has been designed and built for applications that are Commercial and/or Industrial in nature, operation, function 

and location. If the control panel is to be used in Domestic/Residential applications, further consideration is required by the installer 

to ensure its suitability. It is the responsibility of the installing electrician to ensure compliance with relevant standards.

• 

Prior to installation, ensure power supply is isolated.

• 

Electrical connection to the panel must be carried out in accordance with the following pages.

• 

Additions or modifications to the control panel are not permitted and will void warranty.

• 

The controller is not intended for use by children or infirm persons without supervision.

• 

Repairs to the controller must only be carried out by a suitably qualified electrician.

This operation manual makes use of the following symbols to indicate warnings that must be paid specific attention to:

Damage to equipment or personal harm may occur if this instruction is not followed

 

 

 

 

Electrical risk (electrocution hazard) may occur if this instruction is not followed

 

 

 

 

POWER

ON

TANK

EMPTY

Ball

Valve

Closed

Open

Low Level

Float Switch

Foot

Valve

Pump

240Vac

6Amp max

To House

Mains Water

Reviews: