background image

MATELEC AUSTRALIA.  P 1800 281 282.  F  1300 281 282

[email protected].    WWW.MATELECAUSTRALIA.COM.AU

TROUBLESHOOTING

CALIBRATION

  

Reach setting (Sensitivity)

Reach is the term used to describe the diameter of the more or less circular detection zone produced on the ground 

after mounting the sensor at a height of 2.5m.

Turn the reach control fully anti-clockwise to select minimum reach (approx. 2m dia), and fully clockwise to select 

maximum reach (approx. 20m dia).  Adjust according to location and site requirements. 

Time setting

The light can be set to stay ON for any period of time between approx. 5sec (turn fully anticlockwise) and a 

maximum of 12min (turn fully clockwise). Any movement detected before this time elapse will re-start the timer. 

It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test. 

NOTE: 

After the light switches OFF, it takes approx. 1 sec before it is able to start detecting movement again.

The light will only switch on in response to movement once this period has elapsed.

Light-control setting

The chosen light response threshold can be adjusted from approx. 2-2000lux. Turn it fully anti-clockwise to select 

dusk-to-dawn operation at about 2 lux.

Turn it fully clockwise to select continuous daylight operation . 

The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in 

daylight, then adjust setting according to site requirement.   

 

 

5sec~15min

5sec~12min

2~2000LUX

2~2000LUX

1-8m dia

2-20m dia

Malfunction

Cause

Remedy

The load will not work 

Adjust Setting

The load is always on

Load faulty

Change Load

The load is ON without 

movement

Mains is switched OFF

Switch ON

Securely mount 

enclosure

(movement behind wall, movement of a small object

in immediate lamp vicinity etc)

The load will not work

despite movement

Rapid movements are being suppressed to

minimise malfunctioning or the detection zone you

have set is too small.

Check zone setting

Wrong light control selected

Continuous movement in the detection zone

The sensor not mounted for detecting movement 

reliably

Check zone setting

Check zone setting