3 (10)
Svenska Avloppscenter AB
Ekebyvägen 4, 725 92 Västerås
+46 10
490 10 50
Placement
Bio Filter 10 must be placed on a stable and a flat frost-free surface. If Bio Filter is to perform
during the winter, it must be insulated in such a way that the container does not freeze.
Bio Filter 10 must also stand in such a way that it is easy to lift the lid off and inspect
and, if necessary, clean the filter material in the box - under normal conditions 1-2
times a year.
The inlet grey water
is connected to the short side that has only one inlet hole of 75mm (as
well as drainage plugs at the bottom).
The pipes for Bio Filter 10 must tilt at least 1% (1cm per meter) to ensure that wastewater is
standing in the pipes. If it is slow to push the pipes through the sleeves, we recommend that
you use lubricants.
Outgoing water
is connected in the lower hole on the short side with two 75mm holes.
The purified water can be led directly to a ditch, if there is no possibility then we recommend
a recipient to help the ground receive the outgoing water.