MATALA Aqua2use GWDD Installation And Operating Instructions Manual Download Page 4

14.

Finally fit the Aqua2use GWDD tank cover 

Q

 to the tank and lock it using the two 

Stainless steel clips provided.

15.

The Aqua2use GWDD unit can be buried and backfilled with clean loose sand up 

to the outside lip on the main container. Maximum burying depth is 400mm (15.7”). Make 
sure the lid is still accessible and that dirt or other material will not enter the unit or 
interfere with the bypass valve.

Your Matala Aqua2use GWDD unit is now ready for operation. 

GRAVITY OPERATION OF MATALA AQUA2USE GWDD UNIT 

1.

The assembly of the Gravity operated unit is exactly the same as the Pump operated unit. 
The difference is that the discharge point is now the same as the drain point in the pump 
system.  It is not recommended to bury a gravity system.

2.

Because you are not using a pump to produce the head pressure to move the water out of 
the Aqua2use GWDD, it is critical that the location of the Gravity unit is of sufficient height 
to operate the drip system.
Generally 1 metre (40 inch) is the absolute minimum head required.
Please refer to manufactures recommendations as this will differ between products. 

3.

Connect a length of 25mm (1”) lilac pipe from the point 

M

 to your dripper system. Using a 

larger pipe will mean less friction loss. This is critical for the efficient operation of a gravity 
system.

4.

Fit a bypass tee and two inline vales to this pipe before it connects to the drip system.
Both valves are located on the downstream sides of the tee. 
By opening one valve and closing the other this will allow you to flush out any left over 
sludge after you clean the filters. The drain flush line can be plumbed back to your sewerage 
system.

TROUBLE SHOOTING

Water does not flow into 

Check the diverting valve, reset to correct position.

Summary of Contents for Aqua2use GWDD

Page 1: ...Installation and Operating Instructions Congratulations you are now the proud owner of an Aqua2use GWDD CLICK ANYWHERE on THIS PAGE to RETURN to GREYWATER FLUSH TOILETS at InspectApedia com ...

Page 2: ...e concrete slab as a stable base making sure that the unit is level and the drain point M is accessible Assemble and fit the drain assembly M Ensure the backing nut is tight The fitting on the drain has a 25mm 1 thread and plug provided and the outside diameter is suitable for 40mm 1 5 DWV pipe This should be plumbed back to your waste pipe for ease of cleaning The plumber can fit an inline valve ...

Page 3: ...rred in transit 7 Starting at the inlet basket end install the MATALA filter media in the tank Starting with BLACK then GREEN Make sure the filters slide all the way home to fit snug to the bottom of the unit 8 Now install GREEN and BLUE filters Again Make sure the filters slide all the way home to fit snug to the bottom of the unit 9 Now you are ready to install the last two MATALA filters in ord...

Page 4: ... using a pump to produce the head pressure to move the water out of the Aqua2use GWDD it is critical that the location of the Gravity unit is of sufficient height to operate the drip system Generally 1 metre 40 inch is the absolute minimum head required Please refer to manufactures recommendations as this will differ between products 3 Connect a length of 25mm 1 lilac pipe from the point M to your...

Page 5: ...el is high on inlet side Service and clean the filter media to maintain Flow Grey Residual is building up around the Pump Check the filter media make sure it is seated correctly and that there are no voids under the filter mats which will cause bypass around the filters Your unit could need servicing Offensive odours are released from your unit Thoroughly clean the unit and the filter media Make s...

Page 6: ...eywater entering the unit 2 Remove the Stainless Steel clips from the unit Then remove the lid 3 You can now access the MATALA filter media 4 For PUMP OPERATED UNITS it is advised to drain the unit via the drain fitting M 5 For GRAVITY OPERATED UNITS you need to open your drain valve on the bypass tee 6 If you don t have this installed remove the pipe from the bottom fitting M and fit a temporary ...

Page 7: ... no residual remaining in the unit The EPC also avoids the use of an external clock which will easily be disrupted by temporary shutdown of electrical supply No electrician is required and only one standard 10amp outlet is needed to be connected to operate the unit All government departments are pushing for low or no residual water in Grey Water Gray Water Diverters Your Aqua2use GWDD meets or exc...

Page 8: ...g along with the Matala filter mats GRAVITY OPERATION OF THE AQUA2USE GWDD To start up the unit Direct the diverting valve B to allow grey water gray water to divert into the unit Ensure you have positioned the unit with enough height head to operate the irrigation system Minimum requirements will have to be calculated out on site Grey water Gray water will flow through the filters and out to your...

Page 9: ...faulty if inside the warranty period and the fault was no caused by misuse Incorrect installation or operation of your unit is not covered by warranty Damages incurred to persons or property by incorrect operation or installation of your unit are not covered by this warranty Warranty commences from date of purchase please provide proof of purchase with all warranty claims ...

Reviews: