background image

Technical data

The data plate is located on the front of the appliance and
contains all the data needed for connecting it up to the
mains electricity supply.

005-03 - Electric fryer

4

FRYER

Model

ABC00003

ACC00003

ACC00008

ABC00005

ACC00010

ABC00004

ACC00004

ACC00009

ACC00005

Dim.: LxWxH

400 x 615 x 300

400 x 700 x 875

400 x 700 x 300

600 x 615 x 300

600 x 700 x 875

600 x 700 x 300

400 x 615 x 300

400 x 700 x 875

400 x 700 x 300

400 x 700 x 875

800 x 700 x 875

Voltage rating

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

230 V 3 AC or 400 V 3N AC

Power

7.5 kW

7.5 kW

7.5 kW

15.0 kW

15.0 kW

15.0 kW

6.2 kW

6.2 kW

6.2 kW

12.0 kW

24.0 kW

Lead wire / Section

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 6 mm

2  

or 

 

5 x 2.5 mm

2

4 x 6 mm

2  

or 

 

5 x 2.5 mm

2

4 x 6 mm

2  

or 

 

5 x 2.5 mm

2

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 2.5 mm

2  

or 

 

5 x 1.5 mm

2

4 x 6 mm

2  

or 

 

5 x 2.5 mm

2

4 x 10 mm

2  

or 

 

5 x 6 mm

2

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

Summary of Contents for ABC0003

Page 1: ...005_03 Instructions for installation use and maintenance ELECTRIC FRYER 04 2006 ABC0003 ABC0005 ABC0004 ACC0003 ACC0004 ACC0005 ACC0008 ACC0010 ACC0009 ...

Page 2: ...allation 5 Wiring 5 Unipotential 5 Start up 5 Using the appliance 6 Ignition 6 Emptying the bath 6 Cleaning and taking care of the appliance 6 What to do if not using the appliance for a long time 6 What to do if something goes wrong 6 Maintenance 6 WEEE Directive 7 Wiring diagrams 8 12 Warning 13 INDEX 005 03 Electric fryer 2 ...

Page 3: ...00009 400 x 700 x 510 Weight approx 21 kg ABC00003 400 x 650 x 270 Weight approx 21 kg ACC00008 400 x 700 x 510 Weight approx 21 kg ABC00005 600 x 650 x 270 Weight approx 33 kg ACC0010 600 x 700 x 510 Weight approx 33 kg ACC00004 400 x 700 x 875 Weight approx 51 kg ACC00003 400 x 700 x 875 Weight approx 51 kg 600 x 700 x 875 Weight approx 85 kg 400 x 700 x 875 Weight approx 53 kg ACC00005 800 x 70...

Page 4: ...5 mm2 or 5 x 1 5 mm2 4 x 2 5 mm2 or 5 x 1 5 mm2 4 x 2 5 mm2 or 5 x 1 5 mm2 4 x 6 mm2 or 5 x 2 5 mm2 4 x 6 mm2 or 5 x 2 5 mm2 4 x 6 mm2 or 5 x 2 5 mm2 4 x 2 5 mm2 or 5 x 1 5 mm2 4 x 2 5 mm2 or 5 x 1 5 mm2 4 x 2 5 mm2 or 5 x 1 5 mm2 4 x 6 mm2 or 5 x 2 5 mm2 4 x 10 mm2 or 5 x 6 mm2 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 I...

Page 5: ...iance should be carried out in compliance with all local standards and regulations The manufacturers decli ne all responsibility where poor performance is due to in correct installation in disregard of the above conditions Warning In compliance with international regulations when connecting the appliance to the mains power supply a device with a minimum aperture of 3 mm between con tacts must be f...

Page 6: ...us A bowl with these re quisites is available separately as an optinal extra from our sales department Fit the drainage pipe as shown in the picture 2 Open the oil drain tap Important With Top models make sure you respect the distance between the appliance and the edge of the base CLEANING AND TAKING CARE OF THE MACHINE Warning Never clean the appliance with jets of water whether direct or pressur...

Page 7: ...seller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can be sent off for environmentally compatible recy...

Page 8: ...1 A2 P4 B1 B2 P3 P2 4 3 2 mC R N L3 L2 L1 P1 1 1 3 5 13 2 4 6 11 21 31 12 22 32 14 F1 H1 H2 F2 C1 A1 A2 P4 B1 B2 P3 P2 4 3 2 mC R N L3 L2 L1 P1 1 400 V 3N AC 400 V 3N AC ABC00003 ACC00003 ACC00008 ABC00005 ACC00010 mA mC B1 B2 C1 F1 F2 H1 H2 R Line input terminal board Commutating terminal board Switch Microswitch Contactor Working thermostat Safety thermostat Green pilot lamp Orange pilot lamp Re...

Page 9: ...A2 P4 B1 P3 P2 4 3 2 mC R N L3 L2 L1 P1 1 1 3 5 2 4 6 11 21 31 12 22 32 F1 H1 H2 F2 B2 C1 A1 A2 P4 B1 P3 P2 4 3 2 mC R N L3 L2 L1 P1 1 230 V 3 AC 230 V 3 AC ABC00003 ACC00003 ACC00008 ABC00005 ACC00010 mA mC B1 B2 C1 F1 F2 H1 H2 R Line input terminal board Commutating terminal board Switch Microswitch Contactor Working thermostat Safety thermostat Green pilot lamp Orange pilot lamp Resistance Wiri...

Page 10: ...A1 A2 C2 P1 P2 1 2 R1 T2 B2 T1 H2 H1 B1 L1 L2 L3 N mA 400 V 3N AC L1 L2 L3 mA 230 V 3 AC C1 12 P2 P2 ABC00004 ACC00004 ACC00009 mA B1 B2 T1 T2 C1 C2 R1 H1 H2 Line input terminal board Switch Microswitch Thermostat Safety thermostat Contactor Resistance Green pilot lamp Orange pilot lamp Wiring diagrams ...

Page 11: ...F1 F2 B2 mC C1 C2 R 1 2 3 11 12 13 mC 1 11 12 13 2 3 mA mC B1 B2 C1 C2 F1 F2 H1 H2 R Wiring diagrams Line input terminal board Commutating terminal board Switch Microswitch Safety contactor Adjusting contactor Adjusting thermostat Safety thermostat Green pilot lamp Orange pilot lamp Resistance ...

Page 12: ...B1 F1 mC C1 C2 R 1 mA 2 3 4 L1 L2 L3 230 V 3 mC V Y X Z U W F2 B2 mA mC B1 B2 C1 C2 F1 F2 H1 H2 R Wiring diagrams Line input terminal board Commutating terminal board Switch Microswitch Safety contactor Adjusting contactor Adjusting thermostat Safety thermostat Green pilot lamp Orange pilot lamp Resistance ACC00005 ...

Page 13: ...DUE TO COPYING OR PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED 005 03 Electric fryer 13 ...

Reviews: