MW8002
Rev 00.00
Page 17 of
25
©| AES Industrial Supplies Ltd | 2019 all rights reserved
Unauthorized reproduction of this manual is prohibited
.
Par
Description
1
Normal use
The welding fume extractor MW8002 has been designed and built for low to medium use.
The cleaner should be used exclusively for mechanical exhaust of smoke, fine dust, gas, gaseous pollutants
in low concentrations through the torch hood or hose, the end of which is connected with the appropriate filler
plug
on
the
door
instead
of
a
treatment
plant
mechanic.
Remember that: the law allows recycling in environment only if it is occasional welding operations.
The manufacturer is not liable for any use other than as described.
Not to do
-
Do not remove the air cleaner filter panels with mechanical function
-
In general, do not dismantle or remove any part of the mechanical treatment plant when it is in use or
connected to
-
Do not insert the power cord in the closures of the panels
-
Do not tamper with the components of the electrical panel
-
Do not run the vacuum cleaner along with the suction nozzle closed
-
Do not pick up liquids
-
Do not place hot objects (eg cigarette butts)
IMPORTANT NOTE
THE EQUIPMENT SHOULD NOT BE USED IN EXPLOSIVE ATMOSPHERE
FUNCTIONING
Par
Description
2
Most frequent faults: causes and remedies
Given that most of the malfunctions occur for improper use of the system, are indicated in the table below
some possible faults that may occur, and the measures to be taken to remedy them.
FAULT TYPE
CAUSES
ACTION
The cleaner suddenly stops
Power outage
Restore the power supply
The fuse is burned
Change
Motor is burned
Repair or change
The yield of the mechanical
cleaner is decreased
Filters are dirty
Repair or change
Fumes are escaping
Wrong installation of the filters
Check the closures of the panels
and seals