background image

 

 

 

User Manual 

 

 

 

Model: FSL100 Laser Fume Extractor

 

 

WWW.FSLASER.COM

 

 
 

 

Summary of Contents for FSL100

Page 1: ...User Manual Model FSL100 Laser Fume Extractor WWW FSLASER COM...

Page 2: ...ain top performance and warranty 2 Unpacking Inspection Please check carefully to ensure that the following listed parts are included If there are any missing or damaged items please contact customer...

Page 3: ...ifications Model FSL100 Specifications Air Inlet Size 4 duct Input Voltage AC110V Maximum Power 200W Noise 60dB Typical Flow Rate 210 CFM Dimensions 17 x 10 x 16 Weight 31 lbs Full Spectrum Laser FSL1...

Page 4: ...on Duct Hose Installation Remove the hose from the package and attach one end of the 4 duct flange on the top cover of the machine and the other end to your Full Spectrum Laser machine s outlet duct D...

Page 5: ...number is 100 which means the machine is running in full speed Flow Button Press this button when the machine is running the number on digital display decreases in multiples of 10 Proper Fan Speed Th...

Page 6: ...X and start the countdown timer For example H005 represents that the machine will shut down automatically in 5 hours This function is useful at the end of the day when you turn the laser off but still...

Page 7: ...suction power of the empty loaded machine is normal it means the filter needs to be replaced Problem 2 The machine shuts down automatically after it is just started Even if you restart the machine the...

Page 8: ...7 If the problem remains after these inspections and maintenance are performed please contact customer service Full Spectrum Laser FSL100 User Manual 2016 Rev A...

Page 9: ...de is facing upwards air inlet direction When the accumulated dust on the Pre filter is over 70 coverage and cannot be cleaned anymore it must be replaced with a new one 2 Middle HEPA Filter Air Flow...

Page 10: ...p place the Lower Activated Carbon Filter at the bottom inside the machine This filter is responsible for removing smells If there is good airflow but the odors are not removed the Activated Carbon Fi...

Page 11: ...er or lower than this temperature range When using the machine the humidity of the gas and the dust sucked into the air inlet should be between the range of 40 80 If the humidity is excessively high t...

Page 12: ...n and or replace the filter elements regularly to ensure proper machine operation The warranty will not cover any losses or damage that may be incurred by the user if instructions are not followed 10...

Reviews: