One can fill the engine via the filling cap on the exhaust
manifold. Fill up till the level is just below the filling cap.
When the engine is on temperature the liquid will expand
and the redundant liquid will be pressed into the expansion
tank. This tank has to be filled up till the mark. When
cooling liquid is not available clean fresh water could be
used with an additive of anti freeze. When using water with
anti freeze the right mixture has to be calculated according
to the information of the supplier of the anti freeze. When
the cooling is based on keel cooling or radiator cooling the
capacity of these coolers and piping has to be taken into
account calculating the right mixture. The cooling liquid in
the engine is pressurised and has a boiling point above
212°F (100°C). The temperature switch in the thermostat
housing switches at 230°F (110°C). When keel cooling or
radiator cooling is applied the cooling system is not
pressurised. There should be a special cap on the
manifold without valves leaving the connection to the
expansion tank open. Refer to the manual on keel cooling
and radiator cooling.
2.5.13 Technical data
Model
WHISPER 6
WHISPER 8
WHISPER 11
GENERAL
RPM
3600
3600
3600
Alternator
water cooled, synchronous
Engine: Mitsubishi diesel, model
L2E
L2E
L3E
Number of cylinders
2
2
3
Displacement
38.75 cu. inch / 635 cm3
38.75 cu. inch / 635 cm3
58.09 cu inch / 952 cm3
Bore X stroke
2.99 x 2.76 inch
76x70 mm
2.99 x 2.76 inch
76x70 mm
2.99 x 2.76 inch
76x70 mm
Combustion air consumption
40cf/m / 1.1 m3/min
40cf/m / 1.1 m3/min
60cf/m / 1,7 m3/min
Continuous power engine
6 kW
7,4 kW
11 kW
Cooling system
indirect cooling by raw water, 2.6-3.5US qpm / 10-14 l/min.
Cooling water pump
PTO driven Mastervolt self priming impeller pump, type M
Fuel lift pump engine
electric pump (12 V DC), additional pump available upon request
Starting battery (optional)
60-90 Ah 12V
Fuel consumption
0.4-1 US gph / 1.5-4 litre/hour, load dependent
Control
Digital Diesel Control including automatic start/stop
ELECTRICAL SPECIFICATIONS
Output voltage
120V or 120V/240V 60 Hz alternating current (AC) single phase – dual voltage
Output rating at powerfactor cos phi = 1
6 kW
7,4 kW
11 kW
Voltage tolerance
± 5%
± 5%
± 5%
Frequency tolerance
± 5%
± 1% *
± 1% *
Alternator
brushless, two pole, synchronous
Voltage regulation:
capacitor
cap AVR (option)
cap AVR (option)
MECHANICAL SPECIFICATIONS
Supply includes
generating set, built into tugged GRP sound shield with steel base plate, mounted
on rubber anti vibration mounts
Dimensions hxwxd
660x495x550 mm
26 x 19.5 x 21.65 inch
660x495x550 mm
26 x 19.5 x 21.65 inch
810x525x615 mm
31.9 x 20.7 x 24.2 inch
Colour
top white, bottom green
Weight (including canopy)
178 kg / 392 Lbs
182 kg / 401 Lbs
210 kg / 463 Lbs
Max. installation angle
25 degrees
25 degrees
25 degrees
Standard supplies
remote panel (+15 m cable), fuel lift pump, expansion tank
Optional mobile
Installation kits, mobile (vehicle) version, non earth return, spare part kits
* Electronic governor