Mastervolt Solar ChargeMaster SCM-N 20 User Manual Download Page 13

 
 
 
 
 

CONFIGURATION 

 

EN / Solar ChargeMaster 20, 40 / November 07

 13

 

6.1.8  Setting of Serial interface 

Description Displays 

Settings 

 

For proper functioning of the PC link, 
selection of the third mode is 
recommended. 
See also section 4.4.1. 
Default: Read in of current data. 

 

 
Read in of current data. 
 
 
Read back of data logger  
 
PC link bidirectional 
communication 
 

 

6.1.9  Individual / factory settings 

Description Displays 

Settings 

 

You can save your current menu 
setting or reset to default factory 
setting in this menu. 

 
 
 
 
 
Keep individual settings 
 
Reset to factory settings 

 

 

Function

Setting

Settings menu

State of Charge

Function

Setting

Settings menu

Summary of Contents for Solar ChargeMaster SCM-N 20

Page 1: ...Solar ChargeMaster SCM N 20 SCM N 40 INTELLIGENT CHARGE CONTROLLER MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com ENGLISH PAGE 1...

Page 2: ...ement of the product Costs for installation labor or shipping of the defective parts are not covered by this guarantee 1 3 Validity of this manual All of the specifications provisions and instructions...

Page 3: ...arly applies to chapter 2 Safety Guidelines and Measures 2 4 Maintenance repair In case of maintenance and repair activities disconnect batteries and PV modules to prevent unintentional damage to the...

Page 4: ...stem For example street lights and road signs are often solar powered Overnight the battery is discharged during a preset time using the nightlight function Dusk to Dawn At day the battery is recharge...

Page 5: ...4V 24V 72 44V 36V With a 12V system the Solar ChargeMaster 40 can supply a maximum power of 480W To connect higher power devices you will need more than one Solar ChargeMaster or change the system vol...

Page 6: ...screws have to carry also the force applied by the wiring Mind the minimum required distance of 10 cm 4 to floor and ceiling this is necessary for ventilation reasons Installation step by step 1 Open...

Page 7: ...ricted Normal operation Unrestricted Battery connected with wrong polarity to Unrestricted Unrestricted Unrestricted Reverse polarity at 24V system no 12V system yes Yes if only the battery is connect...

Page 8: ...conditions are shown in the LCD screen if the Low Voltage Disconnect function shuts off the load output or in case of various other error conditions See chapter 7 for details Figure 9 Load control 5 3...

Page 9: ...n dusk and dawn no real time setting is required It may take some days until the controller has learnt midnight This method can cause some inaccuracy but avoids any clock readjustment The controller s...

Page 10: ...olyte In this menu you can select the proper battery type liquid electrolyte or GEL VRLA AGM according to your PV system to get better charge of your battery The default battery type is liquid electro...

Page 11: ...his menu See section 5 4 2 for details The default nightlight function EVENING is OFF Mid of night 6 1 5 Nightlight function morning settings Description Displays Settings MORNING OFF Morning From to...

Page 12: ...ge Day Night threshold 5 5 11 0 V Solar Voltage Day Night threshold 6 0 12 1 V Solar Voltage Day Night threshold 6 6 13 2 V Solar Voltage Day Night threshold 7 2 14 3 V Solar Voltage In this menu you...

Page 13: ...section 4 4 1 Default Read in of current data Read in of current data Read back of data logger PC link bidirectional communication 6 1 9 Individual factory settings Description Displays Settings You c...

Page 14: ...1 0 V Check if other sources overcharge the battery If not controller is damaged Loads are not supplied flashing symbols Battery wires or battery fuse damaged battery has high resistance Check battery...

Page 15: ...e 13 7 27 4 V 25 C 13 7 27 4 V 25 C Load disconnect voltage 11 0 12 2 22 0 24 4 V depending on setting 11 0 12 2 22 0 24 4 V depending on setting Load reconnect voltage 12 8 25 6 V 12 8 25 6 V Tempera...

Page 16: ...N 40 Is in conformity with the directives and standards 2006 95 EC Electrical Apparatus Low Voltage Directive 89 336 EEC Electromagnetic compatibility directive 93 68 EEC CE marking EN 60730 1 Electr...

Reviews: