1.  GENERAL INFORMATION 

1.1 

Use of this manual 

This  manual  serves  as  a  guideline  for  the  safe  and 
effective  operation  of  the  Multipurpose  Contact 
Output.  Read  the  entire  manual  before  using  the 
Multipurpose Contact Output. Keep this manual in a 
secure place! 

1.2 

Liability  

Mastervolt can accept no liability for: 

 

Consequential damage resulting from the use of 
the Multipurpose Contact Output. 

 

Possible  errors  in  the  included  manual  and  the 
consequences of these.  

 

Use  that  is  inconsistent  with  the  purpose  of  the 
product. 

1.3 

Warranty 

The  Mastervolt  product  warranty  covers  the 
Multipurpose  Contact  Output  for  the  first  two  years 
after  the  purchase  date,  on  the  condition  that  the 
product  is  installed  and  used  according  to  the 
instructions in this manual. 

Installation  or  use  that  do  not  comply  with  these 
instructions  may  result  in  under  performance, 

damage  or  failure  of  the  product  and  may  void  this 
warranty. The warranty is limited to the cost of repair 

and/or replacement of the product. Costs of labor or 
shipping are not covered by this warranty. 

 

CAUTION! 

Never remove the identification label.  
This will void the warranty. 

1.4 

Disclaimer 

Our  products  are  subject  to  continual  development 
and  improvement.  Therefore,  additions  or  modifica-
tions  to  the  products  may  cause  changes  to  the 
technical data and functional specifications. No rights 
can  be  derived  from  this  document.  Please  consult 

our most current Terms & Conditions of Sale. 

1.5 

Correct disposal of this product 

This  product  is  designed  and  manu-
factured with high quality materials and 
components,  which  can  be  recycled 
and reused. Please be informed about 
the local separate collection system for 

electrical  and  electronic  products.  Please  act 
according  to  your  local  rules  and  do  not  dispose  of 
your old products with your normal household waste. 
The  correct  disposal  of  your  old  product  will  help 

prevent  potential  negative  consequences  to  the 
environment and human health. 

2.  OPERATION 

The Multipurpose Contact Output operation is entirely MasterBus based. For information about MasterBus and the 
MasterBus event structure, see www.mastervolt.com. The following table shows the relay functions. 

Monitoring 

Description 

Factory settings  Range 

State 

Relay can be switched On (activate) or Stand by 

Stand by 

Stand by/ Activate 

Override 

Change the state of the relay 

Stand by 

Activate/ Stand by  

Configuration  Description 

Factory settings  Range 

Language 

Set the Multipurpose Contact Output menu language   English 

See specifications 

Device name 

Any name you wish, with 12 characters max 

DC Relay 

0-12 characters 

1 sec pulse 

Option to create a 1 second starting pulse, needed 
for some generators 

Off 

Off, On 

Min. runtime 

Option to use a minimum run time 

Off 

Off, On 

Min. runtime 

Set the minimum run time if selected 

15 minutes 

15 min-45 days 

Max. runtime 

Option to use a maximum run time 

Off 

Off, On 

Max. runtime 

Set the maximum run time if selected 

8 hrs 

15 min-45 days 

Events 

A MasterBus based device can initiate an action at another connected device. This is done by configuring Events. 
A device can act as 

event source

 and as 

event target

Other devices can control the relay of the Multipurpose Contact Output by setting up an event at the source device 
with  the  Multipurpose  Contact  Output  as  target.  The  following  example  shows  how  a  ChargeMaster  uses  the 
Multipurpose Contact Output as a CSI (Charger Status Interface), switching at charger failure. 

Event source 

Event target 

Event command 

Event action 

Failure 

DC Relay 

Activate 

Copy 

On 

DC Relay 

Activate 

Inverted copy 