Mastervolt MasterBus LIN Interface User And Installation Manual Download Page 3

LIN Interface – User and Installation Manual

 

 

 

3

 

 

 

 

 

Steps

1.  Mount the LIN Interface to any flat surface. The LIN Interface comes with 

a DIN rail mount option. Alternatively, use the two mounting holes (1). 

2.  Wire the screw terminal (2). 

a.  LIN B 
b.  LIN Bus Line   
c.  LIN GND 

Make sure that the power cable is fused with a 1A fuse. 

3.  Insert the MasterBus cable (included, 1m) to integrate the interface into 

the MasterBus network. Make sure that the MasterBus network is 
properly terminated at the two ends with a terminator (3). 

4.  A flashing LED (4) indicates that the MasterBus communication is 

working.

 

5.  Use a MasterBus compatible remote control panel such, as the 

EasyView 5 or PC with MasterAdjust software, to monitor the battery. 

See chapter 3 for the LIN Interface MasterBus features. For more information 
refer to the user manual of the remote control panel

 

3  OPERATION 

The LIN Interface requires no configuration. Once installed correctly, it will start operating automatically. The LIN 
Interface, once powered from the LIN side, automatically starts polling the necessary data from the MLI Ultra 
battery via MasterBus. It will translate this data into vehicle conform LIN messages and respond to LIN requests 
received from the vehicle. In case of no active communication on the LIN Bus, the LIN Interface will go to sleep 
mode (disappear from the MasterBus), until the LIN Bus communication becomes active again. 
To maintain the optimal battery capacity, the battery should be charged to 100% every week. 
The following table shows the LIN Interface items displayed on a monitoring device connected to the MasterBus 
network. 

MONITORING 

DESCRIPTION 

ADJUSTABLE RANGE 

General 

 

 

MLI Status 

MLI battery status, is the battery offline or online  

(read only) 

MLI Data 

 

 

SOC 

Battery state of charge in % 

(read only) 

Time remaining 

Time of battery use left at the actual load in hh:mm:ss 

(read only) 

Cap. consumed 

Battery capacity consumed in Ah 

(read only) 

Cap. Remaining 

Battery capacity remaining in Ah 

(read only) 

Voltage 

Battery voltage in V 

(read only) 

Current 

Current measured by the battery in A 

Positive value: charging, Negative value: discharging 

(read only) 

Temperature 

Internal temperature of the battery in °C  

(read only) 

Charge voltage 

Current desired charge voltage in V communicated to the 

vehicle 

(read only) 

Nom. Capacity 

Nominal battery capacity in Ah 

(read only) 

CONFIGURATION   

 

Device 

 

 

Language 

Interface menu language on a monitoring device connected to 

the MasterBus network [default: English] 

(read only) 

Serial # 

The serial number of the LIN Interface 

(read only) 

Name 

User defined device name, visible throughout the MasterBus 

network [default: LIN] 

Up to 12 characters 

1

4

3