Mastervolt DC Master 24/12 50-60A User Manual Download Page 4

 
 
 
 
 
IMPORTANT SAFETY INSTRUCTIONS 

 

 

 

4

 

February 2015 / DC Master 24/12 50A / EN 

 

2  IMPORTANT SAFETY INSTRUCTIONS 

 

 

READ AND SAVE THESE INSTRUCTIONS 

 

 

WARNING 

This chapter describes important safety and 

operating instructions for use of a DC Master 

in residential, recreational vehicle (RV) and 

marine applications.  

 

2.1 GENERAL 

Before using the DC Master, read all instructions and 

cautionary markings on the DC Master, the batteries, 

and all appropriate sections of the manual.  

To reduce the risk of electric shock – Do not expose 

DC Master to rain, snow, spray, moisture, excessive 

pollution and condensing circumstances. To reduce 

risk of fire hazard, do not cover or obstruct the 

ventilation openings. Do not install the DC Master in a 

non-ventilated room, overheating may result. 

Use of an attachment or spare part not recommended 

or sold by Mastervolt may result in a risk of fire, 

electric shock, or injury to persons.  

Do not operate DC Master if it has received a sharp 

blow, been dropped, or otherwise damaged in any 

way; take it to a qualified serviceman.  

To reduce risk of electric shock, disconnect the DC 

Master from both input and output before attempting 

any maintenance or cleaning. Turning off controls will 

not reduce this risk.  

6  Short circuiting or reversing polarity will lead to 

serious damage to batteries, DC Master, wiring as 

well as accessories. Fuses can not prevent damage 

caused by reversed polarity and the warranty will be 

void.  

7  In case of fire, you must use the fire extinguisher 

which is appropriate for electrical equipment. 

If applied in a marine application in the United States, 

external connections to the DC Master shall comply 

with the United States Coast Guard Electrical 

Regulations (33CFR183, Sub part I).  

 

2.2 EXPLOSIVE 

GASES 

 

1  WARNING – RISK OF EXPLOSIVE GASES. 

WORKING IN VICINITY OF A LEAD-ACID BATTERY 

IS DANGEROUS. BATTERIES GENERATE 

EXPLOSIVE GASES DURING NORMAL BATTERY 

OPERATION. FOR THIS REASON, IT IS OF 

UTMOST IMPORTANCE THAT EACH TIME 

BEFORE USING THE DC MASTER, YOU READ 

THIS MANUAL AND FOLLOW THE INSTRUCTIONS 

EXACTLY.  

2  To reduce risk of battery explosion, follow these 

instructions and those published by battery 

manufacturer and manufacturer of any equipment you 

intend to use in vicinity of the battery. Review 

cautionary marking on these products.  

3  DANGER: To reduce the risk of explosion – Never 

use the DC Master in situations where there is danger 

of gas or dust explosion or area in which ignition-

protected equipment is required.  

 

2.3  WARNING REGARDING LIFE SUPPORT 

APPLICATIONS  

The DC Master is not sold for applications in any medical 

equipment intended for use as a component of any life 

support system unless a specific written agreement 

pertaining to such intended use is executed between the 

manufacturer and Mastervolt. Such agreement will require 

the equipment manufacturer either to contract additional 

reliability testing of the DC Master and/or to commit to 

undertake such testing as a part of the manufacturing 

process. In addition the manufacturer must agree to 

indemnify and not hold Mastervolt responsible for any 

claims arising from the use of the DC Master in the life 

support equipment.  

 

2.4 

GUARANTEE SPECIFICATIONS  

Mastervolt guarantees that this unit has been built 

according to the legally applicable standards and 

specifications. Should work take place, which is not in 

accordance with the guidelines, instructions and 

specifications contained in this user’s manual, then 

damage may occur and/or the unit may not fulfil its 

specifications. All of these matters may mean that the 

guarantee becomes invalid.  

The guarantee is limited to the costs of repair and/or 

replacement of the product. Costs for installation labor or 

shipping of the defective parts are not covered by this 

guarantee. Refer to your terms of delivery for the 

guarantee period. 

 

Summary of Contents for DC Master 24/12 50-60A

Page 1: ...aster 24 12 50 60A DC DC converter MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www mastervolt com Copyright 2015 Mastervolt 10000008899 01 Febru...

Page 2: ...TRUCTIONS 4 2 1 General 4 2 2 Explosive gases 4 2 3 Warning regarding life support applications 4 2 4 Guarantee specifications 4 3 INSTALLATION 5 3 1 Before you start 5 3 2 Choosing a location to inst...

Page 3: ...in this manual by the following pictograms WARNING A WARNING refers to possible injury to the user or significant material damage to the converter if the user does not carefully follow the procedures...

Page 4: ...A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING THE DC MASTER YOU READ THIS...

Page 5: ...around the apparatus Do not mount the DC Master straight above the batteries because of possible corrosive fumes 3 3 CONTENTS OF THE DELIVERY DC Master 24 12 50 60A Mounting bracket 4x screws 4x screw...

Page 6: ...Center to solve a problem Problem Possible cause What to do Output voltage is OK Status LED yellow High load Reduce connected load Output voltage is OK Status LED yellow blinking 1Hz Too high load Re...

Page 7: ...ull load 90 No load consumption on off 15 5 mA Temperature range 25 to 80 C 13 to 176 F Load must be reduced at temperatures between 35 and 80 C 86 and 176 F Cooling Natural convection Connections 5 w...

Page 8: ...24 12 50 60A Is in conformity with the provisions of the following EC directives 2004 108 EC EMC directive the following harmonized standard has been applied EN 60945 2002 Maritime navigation and rad...