background image

 
 
 
 
 
 

 

 

 

2

 

December 2008 / Multipurpose Contact Output / EN 

 

1 GENERAL 

INFORMATION 

 

1.1 

Use of this manual 

Copyright © 2008 Mastervolt. All rights reserved. 
Reproduction, transfer, distribution or storage of part 
or all of the contents in this document in any form 
without the prior written permission of Mastervolt is 
prohibited.This manual serves as a guideline for the 
safe and effective operation of the Multipurpose 
Contact Output. Keep this manual at a secure place! 
 

1.2 

Guarantee specifications  

Mastervolt guarantees that this product was built 
according to the legally applicable standards and 
stipulations. If you fail to act in accordance with the 
regulations, instructions and stipulations in this 
user’s manual, damage can occur and/or the 
product will not fulfil the specifications. This may 
mean that the guarantee will become null and void. 
 

IMPORTANT: Additional warranty agreements, like 
“Mastervolt system warranty” may contain 
restrictions which forbid resetting of historical data 
The standard guarantee period is two years after 
date of purchase.  
 

1.3 Liability 

 

Mastervolt can accept no liability for:  

 consequential damage due to use of the 

Multipurpose Contact Output;  

  possible errors in the manuals and the results 

thereof;  

  Use that is inconsistent with the purpose of the 

product. 

 

CAUTION! 
Never remove the identification label. 

 

 

2 OPERATION 

 

2.1 MasterBus 

functions 

The Multipurpose Contact Output operation is entirely MasterBus based. For information about MasterBus and 
the MasterBus event structure, see www.mastervolt.com. The table below shows the relay functions. 
 

Monitoring Function 

Description 

Factory settings 

Range 

State 

Relay can be switched On (activate) or 
Stand by 

Stand by 

Stand by/ Activate 

Override 

Change the state of the relay 

Stand by 

Activate/ Stand by 

Configuration Function 

Description 

Factory settings 

Range 

Language 

Set the Multipurpose Contact Output 
menu language  

English See 

specifications 

Device name 

Any name you wish with 12 characters 
max 

DC Relay 

12 characters max 

1 sec pulse 

Option to create a 1 second starting 
pulse, needed for some generators 

Off Off, 

On 

Min. runtime 

Option to use a minimum run time 

Off 

Off, On 

Min. runtime 

Set the minimum run time if selected 

15 minutes 

15 min-45 days 

Max. runtime 

Option to use a maximum run time 

Off 

Off, On 

Max. runtime 

Set the maximum run time if selected 

8 hrs 

15 min-45 days 

 

2.2 

CSI for ChargeMaster 

The Multipurpose Contact Output can be used as CSI (Charger Status Interface) for the ChargeMaster, switching 
at charger failure. CSI configuration is done at the ChargeMaster under Configuration/ Events: 
 

Event source 

Event target 

Event command 

Event action 

Failure DC 

Relay 

Activate Copy 

On DC 

Relay 

Activate 

Inverted 

copy 

 

Summary of Contents for 77030500

Page 1: ...ERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2008 Mastervolt v 1 3 December 2008 ENGLISH PAGE 1 NEDERLANDS PAGINA 5 DEUTSCH SEITE 9 FRANÇAIS PAGINA 13 CASTELLANO PÁGINA 17 ITALIANO PÁGINA 21 ...

Page 2: ...t with the purpose of the product CAUTION Never remove the identification label 2 OPERATION 2 1 MasterBus functions The Multipurpose Contact Output operation is entirely MasterBus based For information about MasterBus and the MasterBus event structure see www mastervolt com The table below shows the relay functions Monitoring Function Description Factory settings Range State Relay can be switched ...

Page 3: ...gure Mass Charger Multipurpose contact controls Fan Where to configure DC Distribution Multipurpose contact controls Buzzer Where to configure Sunmaster XS XL range Multipurpose contact controls Power supply Where to configure MasterShunt Multipurpose contact controls Generator Source Target Command Command Data Insulation failure Multipurpose Contact Activate Copy Source Target Command Command Da...

Page 4: ...derlands Deutsch Français Castellano Italiano Norsk Svenska Suomi Dansk Power consumption 144 mW MasterBus Powering No Din rail mounting Yes Din rail 30 mm 1 2 inch Protection degree IP 21 Dimensions 66 x 78 x 32 mm 2 6 x 3 1 x 1 3 inch see drawing below Weight Approx 80 gr 0 18 lb Dimensions in mm inch 4 5 0 18 69 2 7 4 0 0 16 33 1 3 33 1 3 6 0 0 24 78 3 1 32 1 3 4 0 0 16 1 Input 2 Output normall...

Reviews: