Mastervolt International Masterlink MICC Quick Start Manual Download Page 2

 

Use of the Masterlink MICC with the Mass Combi

 

 

 

 

 

 

 

Mastervolt International B.V,

    P.O.Box 22947,   NL-1100 DK Amsterdam,   The Netherlands.    

Tel.:

 +31-20-3422100    

Email:

 [email protected]    

Web:

 www.mastervolt.com   v1.2 071206EN 

 

DAILY USE OF THE MASTERLINK MICC: 
Adjustment of the Power sharing / Power 
support level 

When the available current from the AC source is 
limited (for instance to avoid the shore fuse from 
tripping), the maximum AC input current of the Mass 
Combi can be limited. Follow the steps below: 

 

VOLT & CHG.AMP 

 25.54V    0.3A

 

 

VOLT & CHG.AMP 

 25.54V    0.3A

 

Press 

Charger

 once 

 

 

POWER SHARING. 

    25.0A    

Ç

 

Hold 

Select 

pressed for 5 sec. to change the arrow’s 

direction. If pointing upwards (

Ç

), the

 Power sharing / 

Power support

 level can be increased; if pointing 

downwards (

È

), it can be lowered.  

Press 

Set-up

 several times to adjust the 

Power 

sharing / Power support

 level  

After adjustment, press 

Select

 once  

 EXIT LEVEL 
 ->PRESS SET-UP

 

Press 

Set-up

 once.  

Now the Select-LED stops blinking

 

 

VOLT & CHG.AMP 

 25.54V    0.3A

 

Ready! 

 

Hold 

Select

 pressed until the 

Select LED starts blinking

 

Power Support Function 

The 

Power Support Function

 can be enabled by means 

of DIP-switch B-SW4. If enabled and the total demand 
for AC power is more than the 

Power Sharing level

load connected to the 

Short Break

 output will be 

powered by the inverter while load connected to the 

Power

 output will be powered by the external AC-

source. See sections 3.3.5 and 6.2.2 of the user’s 
manual of the Mass Combi for more information. 

 

DIP switch B 

SW4 

Power support function disabled 

OFF  

Power support function enabled 

ON  

INITIAL DIP-SWITCH SETTINGS AT THE MASS COMBI (CONTINUED) 

Generator / mains support function 

With the Generator / mains support function enabled, 
AC power from the inverter is added to both AC outputs 
if the total demand for AC power is higher than the 
Power Sharing level. See section 3.3.4 and 6.2.3 of the 
user’s manual of the Mass Combi for more information. 

 

DIP switch B 

SW5 

Generator / mains support function disabled 

OFF  

Generator / mains support function enabled 

ON  

 

INITIAL SETTINGS AT THE MASTERLINK 
MICC

  

Start from the initial menu to configure the 
Masterlink MICC for use with the Mass Combi. 

 VOLT & CHG.AMP 
 25.54V    0.3A 

Hold 

Select

 pressed until the 

Select LED starts blinking

 

 VOLT & CHG.AMP 
 25.54V    0.3A 

Press 

Set-up

 once 

 

 SLEEP MODE 

      ON 

   HFC mode 

    OFF

 

Press 

Select

 3 times

 

Press 

Set-up

 once to enable the HFC mode

 

   HFC mode 
    ON

 

Press 

Select 

once 

 

 EXIT LEVEL 

 ->PRESS SET-UP

 

Press 

Set-up

 once.  

Now the Select-LED stops blinking 

 

 VOLT & CHG.AMP 
 25.54V    0.3A 

Ready! 

 

7