USER INSTRUCTIONS
INSTALLATION INSTRUCTIONS
IN-LINE RCD
STAGE
1
Insert plug into 13amp mains socket and switch on
STAGE
2
Press the
RESET
button -The
RED
indicator should appear
STAGE
3
Press the
TEST
button - The
RED
indicator will disappear from the
CLEAR
window
DO NOT USE IF THE RED INDICATOR REMAINS
The in-line RCD has been designed to be for heavy duty applications. The water resistant casing of the unit is rated at IP 65.
To maintain the IP 65 weather proof rating of the device, plugs, sockets and connectors of an equivalent rating must be used.
The RCD is a Non-latching RCD type. This means when power to the RCD is disconnected, due to a power cut or switching
of the mains, the RCD will trip & have to be
r
e-set when power returns. The RCD will need to be
r
e-set before power returns
to the connected equipment. Ideal for power tools and garden equipment.
Masterplug Help Line
Visit our website at
www.masterplug.com
Stafford Park 1 Telford TF3 3BD ENGLAND
03300 249 279
Luceco PLC
WHAT IS A SAFETY RCD?
Your Masterplug Safety in-line RCD continuously monitors the power supply to an electrical appliance and cuts off the power
within 40 milliseconds if an earth current fault is detected. This is fast enough to prevent a fatal electrical shock.
Electrical appliances can become dangerous if the wiring becomes loose, if they or their power cords become damaged or if
they get wet. Electrocution is also possible if fingers, wet hair or other conductive bodies enter the appliance. In all cases your
Masterplug safety in-line RCD will instantly cut off the electricity before you or a member of your family receive a potentially
fatal shock.
Before commencing any electrical work ensure the supply is switched off at the mains
, e
ither by switching off the consumer unit
or by removing the appropriate fuse.
The inline RCD is suitable for use with flexible cable -
• Ordinary duty, PVC or Rubber construction*
• 300/500V mains, 3-Core 1.25mm or 1.5mm
• Round profile
• To BS6500 or equivalent
*
PVC insulated & sheathed, Harmonized Code: H05VV-F3 or Rubber insulated
and
sheathed, Harmonized Code: H05RR-F3.
1. For each end of the RCD remove the two screws securing the terminal cover. Disconnect the terminal end caps from the
main body, and push the cable through the seal.
2. Remove the two screws securing the cord grip and set aside
3. Prepare the cable as shown in the diagrams below.
STRIP LENGTH
6-8mm
9-12mm
GREEN YELLOW
STRIP LENGTH
12-15mm
STRIP LENGTH
12-15mm
CORD GRIP
DO NOT INVERT
SECURE CORD GRIP
STRIP LENGTH
6-8mm
9-12mm
GREEN YELLOW
STRIP LENGTH
12-15mm
STRIP LENGTH
12-15mm
CORD GRIP
DO NOT INVERT
SECURE CORD GRIP
4. Loosen the terminal screws and the insert the correct coloured wire into each terminal and tighten.
5. Replace the cord grip ensuring that it grips the outer sheath of the cable and tighten
6. Replace the terminal cover and tighten the two screws.