USER INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IN-LINE RCD

STAGE

 

1

Insert plug into 13amp mains socket and switch on

STAGE

 

2

Press the 

RESET

 button -The 

RED

 indicator should appear

STAGE

 

3

Press the 

TEST

 button - The 

RED

 indicator will disappear from the 

CLEAR

 window

 

DO NOT USE IF THE RED INDICATOR REMAINS

The in-line RCD has been designed to be for heavy duty applications. The water resistant casing of the unit is rated at IP 65. 

To maintain the IP 65 weather proof rating of the device, plugs, sockets and connectors of an equivalent rating must be used.
The RCD is a Non-latching RCD type. This means when power to the RCD is disconnected, due to a power cut or switching 

of the mains, the RCD will trip & have to be 

r

e-set when power returns. The RCD will need to be 

r

e-set before power returns 

to the connected equipment. Ideal for power tools and garden equipment. 

Masterplug Help Line

Visit our website at

www.masterplug.com

Stafford Park 1 Telford TF3 3BD ENGLAND

03300 249 279

Luceco PLC

WHAT IS A SAFETY RCD?

Your Masterplug Safety in-line RCD continuously monitors the power supply to an electrical appliance and cuts off the power 

within 40 milliseconds if an earth current fault is detected. This is fast enough to prevent a fatal electrical shock. 
Electrical appliances can become dangerous if the wiring becomes loose, if they or their power cords become damaged or if 

they get wet. Electrocution is also possible if fingers, wet hair or other conductive bodies enter the appliance. In all cases your 

Masterplug safety in-line RCD will instantly cut off the electricity before you or a member of your family receive a potentially 

fatal shock.

Before commencing any electrical work ensure the supply is switched off at the mains

, e

ither by switching off the consumer unit 

or by removing the appropriate fuse.
The inline RCD is suitable for use with flexible cable -
• Ordinary duty, PVC or Rubber construction*
• 300/500V mains, 3-Core 1.25mm or 1.5mm
• Round profile
• To BS6500 or equivalent
*

 

PVC insulated & sheathed, Harmonized Code: H05VV-F3 or Rubber insulated 

and

 sheathed, Harmonized Code: H05RR-F3.

1. For each end of the RCD remove the two screws securing the terminal cover. Disconnect the terminal end caps from the

main body, and push the cable through the seal.
2. Remove the two screws securing the cord grip and set aside
3. Prepare the cable as shown in the diagrams below.

STRIP LENGTH

6-8mm

9-12mm

GREEN YELLOW

STRIP LENGTH

12-15mm

STRIP LENGTH

12-15mm

CORD GRIP

DO NOT INVERT

SECURE CORD GRIP

STRIP LENGTH

6-8mm

9-12mm

GREEN YELLOW

STRIP LENGTH

12-15mm

STRIP LENGTH

12-15mm

CORD GRIP

DO NOT INVERT

SECURE CORD GRIP

4. Loosen the terminal screws and the insert the correct coloured wire into each terminal and tighten.
5. Replace the cord grip ensuring that it grips the outer sheath of the cable and tighten
6. Replace the terminal cover and tighten the two screws.