background image

© 2020 Menard, Inc., Eau Claire, WI 54703

03/2020

Summary of Contents for 260-9520

Page 1: ...To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference 260 9520 0099002187 00 1000W Power Converter...

Page 2: ...placement Parts Page 7 Before Using Your Converter Page 7 Fastening the Converter to a Flat Surface Page 8 Connecting Converter Cables Page 8 Battery Bank Instructions Page 9 Operating Instructions Pa...

Page 3: ...Volts Voltage A Amperes Current Hz Hertz Frequency W Watts Power Alternating current Type of current Direct current Type or characteristic of current Class II construction Double insulated constructi...

Page 4: ...t in electric shock fire and or serious personal injury SYMBOL MEANING SAFETY ALERT SYMBOL Indicates DANGER WARNING or CAUTION May be used in conjunction with other symbols or pictographs Failure to o...

Page 5: ...e converter 1 11 Do not place the converter in areas such as battery compartments or engine compartments where fumes or gases may accumulate 1 12 DO NOT operate the converter if you the converter the...

Page 6: ...ding gravity or filling battery 3 3 Do not operate converter in a closed in area or restrict ventilation in any way 4 FEATURES ON OFF rocker switch LED indicator Green indicates Power ON Red indicates...

Page 7: ...erter with a product that draws a higher wattage than the converter can provide as this may cause damage to the converter and product When you turn on a device or a tool that runs on a motor the devic...

Page 8: ...ter with any of these devices may cause the device to run warmer or overheat Fig 1 Modified sine waveform produced by converter Fig 2 Pure sine waveform typical of home AC outlet IMPORTANT If you are...

Page 9: ...ground electrical systems connect the POSITIVE RED ring terminal from the converter to the POSITIVE POS P ungrounded post of the battery Connect the NEGATIVE BLACK ring terminal to the vehicle chassi...

Page 10: ...8 Connect the output cables from the battery bank to the converter 12V lead acid battery 200 Ah Connect additional 12V 200 Ah lead acid batteries here to increase capacity 12V lead acid battery 200 A...

Page 11: ...e to ineffective filters in the sound system s power supply Unfortunately this problem can only be resolved by purchas ing a sound system with a higher quality power supply or higher quality filter US...

Page 12: ...converter to the continuous rated output RESET To reset after shutdown occurs switch the converter s ON OFF switch to the OFF O position Check the source of the problem and correct Switch the converte...

Page 13: ...lace the battery Use a higher capacity converter do not use with this equipment Allow converter to cool Check for adequate ventilation Reduce the load on the converter to the rated continuous power ou...

Page 14: ...warranty 1 excludes expendable parts includ ing but not limited to blades brushes belts bits light bulbs and or batteries 2 shall be void if this product is used for commercial and or rental purposes...

Page 15: ...Page 15 NOTES...

Page 16: ...2020 Menard Inc Eau Claire WI 54703 03 2020...

Reviews: