Note: A circuit breaker is recommended. If the air compressor is connected to a
circuit protected by a fuse, use dual element time delay fuses (Buss Fusetron type “1”
only).
Extension Cord
Note: Avoid use of extension cords.
For optimum performance, plug the compressor power cord directly into a grounded wall socket. Do
not use an extension cord unless absolutely necessary. Instead, use a longer air hose to reach the
area where the air is needed.
If use of an extension cord cannot be avoided, the cord should be no longer than 100’ and be a
minimum wire size of 12 gauge (AWG). Do not use a 16 or 14 gauge extension cord.
Use only a three-pronged extension cord that has a 3-pronged grounding plug, and a 3-slot receptacle
that will accept this plug. Make sure your extension cord is in good condition. An undersized
cord will cause a drop in line voltage, resulting in loss of power and overheating. The smaller
the gauge number, the heavier the cord.
Grounding Instructions
This product should be grounded. In the event of an electrical short circuit or current leakage,
grounding reduces the risk of electric shock by providing a path for the electric current. Consult with an
electrician if necessary.
This product is equipped with a three-pronged grounded power cord and plug. The plug must be
plugged into an outlet that is properly installed and grounded accordance with all local codes and
ordinances. Never modify the plug.
WARNING!
IMPROPER INSTALLATION OF THE GROUNDING PLUG
CAN RESULT IN A RISK OF ELECTRIC SHOCK. IF REPAIR OR
REPLACEMENT OF THE CORD OR PLUG IS NECESSARY, DO NOT
CONNECT THE GROUNDING WIRE TO ANY FLAT BLADE TERMINAL. THE
GROUND WIRE IS EITHER GREEN WITH OR WITHOUT YELLOW STRIPES
AND MUST BE CONNECTED TO THE "GROUND" PIN OF THE PLUG.
This product is for use on a nominal 115 V, 15 A circuit. An outlet with a grounding plug must be
used.
Make sure that the product is connected to an outlet with the same configuration as the plug. No
adaptor should be used with this product.
Breaking in the Pump
1.
Turn the pressure switch to the OFF position (A, Fig J).
2.
Pull
the pressure relief valve.
3. Open the regulator valve (D, Fig J). Turning counter-clockwise.
4.
Plug in the power cord.
5. Turn the pressure switch to the ON position (C, Fig J). The compressor will start. Allow the
compressor to run for 15 minutes, to break in the internal parts.
CAUTION: AFTER ABOUT 15 MINUTES IF THE UNIT DOES NOT OPERATE
PROPERLY SHUT DOWN IMMEDIATELY AND CONTACT A SERVICE CENTER.
21