PRODUCT NUMBER 

058-7000-2

PEAK HORSEPOWER 

1/3

TANK SIZE 

2 U.S. GALLONS 

(7.6 L)

AIR DELIVERY (SCFM*) @ 40 PSI  1.0

AIR DELIVERY (SCFM*) @ 90 PSI  0.7

CUT-IN PRESSURE (PSI) 

85

CUT-OUT PRESSURE (PSI) 

100

FUSE 

3 A, 5 x 20 mm

POWER 

120 V, 60 Hz, 2.6 A

WEIGHT 

16 lb 

(7.3 kg)

POWER CORD 

STJ 18 AWG / 6'

 (1.82 m)

EXTENSION CORD 

SJT 16 AWG / MAXIMUM 50’

 (15 m)

* SCFM:

 

Standard Cubic Feet per Minute

 (=

 

The volumetric flow rate of a gas 

corrected to standardized conditions of temperature and pressure.)

This manual contains information that relates to 

PROTECTING 

PERSONAL SAFETY

 and 

PREVENTING EQUIPMENT PROBLEMS

. It 

is very important to read this manual carefully and understand 
it thoroughly before using the product. The symbols listed 
below are used to indicate this information.

DANGER! 

Potential hazard that will result in serious injury or loss of life. 

WARNING!

 Potential hazard that could result in serious injury or loss of life. 

CAUTION! 

Potential hazard that may result in moderate injury or damage to equipment.

IMPORTANT!

 Installation, operation or maintenance information that is important but 

not hazard related.

Safety Advice

DANGER!

1. 

RISK OF FIRE OR EXPLOSION. 

Do not spray a flammable or combustible liquid or 

paint near sparks, flames, pilot lights or in a confined area. The spray area must be 
well-ventilated. Keep compressor at least 20’ (6 m) away from spray area. Do not 

carry and operate the compressor or any other electrical device near the spray area. Never smoke 
when spraying. Use a minimum of 25’ (7.6 m) of hose to connect a spray gun to the compressor.

2. 

RISK OF ELECTRIC SHOCK. 

Do not expose to rain. Store indoors. Hazardous voltage. 

Disconnect from power source before servicing. Compressor must be grounded. Do 
not use grounding adaptors.

3. 

RISK OF BURSTING.

 Make sure the regulator is adjusted so that the compressor outlet 

pressure is set lower than the maximum operating pressure of the spray gun or tool. 
Before starting the compressor, pull the ring on the safety valve to make sure the valve 
moves freely (see diagram on page 18). Drain water from tank after each use. Do not 
weld or repair tank.

SA

FE

TY

 G

UI

DEL

IN

ES

058-7000-2-Air-Compressor-2G-EN-03.indd   3-4

6/11/12   8:14 AM

Summary of Contents for 058-7000-2

Page 1: ...ughly before using the product It contains important information for your safety as well as operating and maintenance advice Keep this instruction manual for future use Should this product be passed o...

Page 2: ...5 Plug in the power cord STEP 4 Close the tank drain valve located on the bottom of the air tank TABLE OF CONTENTS QUICK START GUIDE TECHNICAL SPECIFICATIONS 3 SAFETY GUIDELINES 4 6 KEY PARTS DIAGRAM...

Page 3: ...at may result in moderate injury or damage to equipment IMPORTANT Installation operation or maintenance information that is important but not hazard related Safety Advice DANGER 1 RISK OF FIRE OR EXPL...

Page 4: ...se and the power cord from damage and puncture Inspect them for weak or worn spots every week and replace them if necessary 4 Always wear hearing protection when using an air compressor Failure to do...

Page 5: ...ssure from the system when it reaches a preset level if the pressure switch has not shut down the motor It will pop open automatically or it can be activated manually by pulling the ring on the valve...

Page 6: ...g used again Do not exceed the maximum working time Compatible compressor air tool proper usage operation Always ensure the use of appropriately matched air tools with your Mastercraft Air Compressor...

Page 7: ...stable wrench 1 Cross headed screwdriver 1 2 Check the air compressor s identification label to ensure that you have purchased the intended model and that it has the required pressure rating for its i...

Page 8: ...outlet K on the air compressor Hose connector Air outlet K 5 Attach other accessories End of hose or low gun Tire chuck or quick connector Blow gun adaptor Tapered nozzle or inflation needle NOTE Tire...

Page 9: ...temperatures are generated by the electric motor and the pump To prevent burns or other injuries DO NOT touch the air compressor while it is running Allow it to cool before handling or servicing Keep...

Page 10: ...ntire unit to protect it from moisture and dust Store the air compressor in a clean and dry location In cold weather store the compressor in a warm building when it is not in use This will reduce prob...

Page 11: ...d by the compressor a larger capacity air compressor is needed Most accessories are rated at 25 of actual SCFM while running continuously PROBLEM POSSIBLE CAUSES SOLUTIONS The regulator does not regul...

Page 12: ...flat washer 6 4 11 paper pad 3 36 screw M6 15 4 12 silica gel ring 21 2 1 37 drain valve 1 13 piston ring 1 38 internal tooth washer 1 14 connecting rod 1 39 wire clip 1 15 clamp 1 40 screw M4 15 3 16...

Page 13: ...This warranty will not apply to any product or part thereof which is worn or broken or which has become inoperative due to abuse misuse accidental damage neglect or lack of proper installation operat...

Reviews: