32
INFO: SW, LANGUAGE, DB
F1
F2
F3
F4
F5
F6
At the MAIN MENU select INFO F3.
■
INFO MENU
Data
Counters
Filter Conditions
Ref Management
Password
Info: SW, Language DB
↵
↑
↓
Select INFO: SW, LANGUAGE DB, press F4
↵
:
SOFT VERSION
SW: x.xx
DBA: xxxxxxxxx
Text: xx.xx
F2 to exit
■
This screen displays the name of the current software revision and the current database software that is loaded in the machine’s memory.
ROUTINE MAINTENANCE
VACUUM PUMP
Perform the operations listed below on a routine basis in order to ensure the best operation of the vacuum pump:
When filling or replacing the pump oil, use only the oil recommended by the manufacturer.
MAX
MIN
2
3
MIN
MAX
4
5
6
90016
VACUUM PUMP OIL
16 oz (450ml)
FIG. 8
OIL FILL - (NEW MACHINE)
This vacuum pump has been tested at the factory and shipped with only trace amounts of oil. OIL MUST BE ADDED BEFORE OPERATING! Failure to
add oil will damage the cartridge and void warranty.
NOTE:
Make sure the oil drain valve located below the front casing is closed before attempting to add oil (Fig 8-3.)