 File Management

Browse images from the micro SD card
Note: If you want to manage images, please use the USB 
cable to connect the device and the computer)

 Settings

Emissivity

The default emissivity is 0.95, or select other default emissivity: 

Blackbody: 1.0,

 

Matt: 0.95, Semi-matt: 0.8, Semi-glossy: 

0.6, Glossy: 0.3 

Select Set Value to adjust the emissivity (0.1 to 1, in 0.01 steps)

HAL

When the reading is outside the High Alarm (HAL) or Lo Alarm 
(LAL) limit, the reading (HAL: red texts, LAL: blue texts) shown 
at the top left corner of  the screen will flash with two short 
beep sounds constantly.
Select 

Set HA

 temp or 

Set LA

 temp to adjust the limits or 

select ON/OFF to turn on/off the alert.

LAL

Save file as Save the file as 

photograph

 or 

record

Auto off

The default setting is “Auto off 1 min”, you can select other de-
fault values: 

5, 10, 20 minutes or “No auto off”

. Manually power 

off the device by pressing Power [   ] key (2) for 3 seconds.

Target 
distance

The maximum distance between the thermal imaging camera 
and the target: 

1m, 2m or 3m

Languages Select: 

English/French/Spanish/Portuguese/German/

Dutch/Italian/Traditional Chinese/Simplified Chinese

Set time 
and date

Set the date and time in 

MM/DD/YYYY

 (month/day/year) and 

HH/MM/SS

 (hour/minute/second) formats.

STORAGE & CLEANING

The thermal imaging camera should be stored at room temperature. The sensor lens is 
the most delicate part of the thermometer. The lens should be kept clean at all times, care 
should be taken when cleaning the lens using only a soft cloth or cotton swab with water 
or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do not 
submerge any part of the thermometer.

BATTERIES

The thermometer incorporates visual low battery indication as follows:

O

O

p

p

e

e

r

r

a

a

t

t

i

i

n

n

g

g

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

f

f

o

o

r

r

 

 

T

T

I

I

M

M

0

0

3

3

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

I

I

m

m

a

a

g

g

e

e

r

r

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature. 
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report 
generation from these saved images.

 

 

OPERATION 

1.

 

Power on 
Press Mode Key (

2

) or Trigger (

10

) to power on the unit. 

2.

 

Taking a thermal image and temperature 
After  power  on, simply  aim the thermal  imager  camera  at the  measure target  with  Lens 
(

9

)  and  get  the  thermal  image  and  temperature  immediately.  Please  make  sure  the 

target area is within the field of view. 
Note:  There  are three  cursors  on the  screen. The  cross  sign  shows the temperature of 
the  object  located  in  the  middle  of  the  screen.  Other  two  moving  cursors  indicate  the

 

highest and lowest temperatures in the thermal image. 

3.

 

Save thermal images 
Press Trigger (

10

) to save the thermal image to the micro SD card, press Up Key (

3

) or 

Down Key (

4

) to  show the  saved images. Press Mode  Key (

2

) again  to return to the 

measurement screen.

 

4.

 

Color palettes 
Press Color Palette Key (

6

) to select the color palette (4 selectable color palettes) to view thermal images. 

 

 

 

 

Ironbow 

Rainbow 

High contrast 

Grayscale 

5.

 

C/°F/K 

Press Unit Key (

5

) for  C

°F or K transferred. 

6.

 

Power off 

        Press Mode Key (

2

) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..

 

 
FUNCTIONS 

Press  Mode  Key  (

2

)  for  scrolling  more  display  functions,  then  press  Up  key  (

3

)  or  Down  key  (

4

)  to  change  the 

functions, then press Trigger (

10

) to confirm it. 

Emissivity 

The default emissivity is 0.95, or select other default emissivity: Matt:0.95Semi-matt:0.8Semi-glossy:0.6
Glossy:0.3 
Select Set value to adjust the emissivity (0.1 to 1 step .01). 

HAL 

You  can  select  Set  Min  temp  or  Set  Max  item  to  adjust  the  High  Alarm  (HAL)  or  Lo  Alarm  (LAL)  limits 
(step .1). 

LAL 

Language 

Selectable Chinese or English

Backlight 

Selectable 5 levels of brightness. 

Set Time 

Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats. 

Time stamp 

Turn on Time stamp to save thermal images with real-time stamp.   
Turn off Time stamp to hide date and time on stored thermal images. 

Erase Image 

Select Yes, All image! to clear all stored thermal images. 

Reset 

Select Reset to recover the factory setting data. 

Set parameter 

Select Use Median Value

 

to reduce noise in an image. 

Select No Filter

 

to display real image noise. 

 
STORAGE & CLEANING       

It  should  be  stored  at  room  temperature.  The  sensor  lens  is the most  delicate  part  of the  thermometer.  The  lens  should  be  kept 
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. 
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.   

 
BATTERIES
 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. 

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

 

SPECIFICATION 

Thermal Image Resolution 

32*31 

Measurement Range 

-20~250°C (-4~482°F) 

Accuracy (Tamb=20~26°C) 

2% of reading, or 2°C(4°F) whichever is greater 

Thermal Sensitivity 

0.1°C 

Frame Rate 

9Hz 

Field of View 

40*40 deg 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

Focus 

Focus free 

LCD (inch) 

2.8 

LCD Type 

Color 

Image Storage 

Stores up to 60000 images/GB, 

Bitmap (BMP) file format.

 

Memory Type 

Support 8G micro SD card 

Sensor Filter (um) 

8~14um 

Interface 

USB 

Battery Type 

AA*4 

Battery Life (hr)(backlit) 

6   

Dimensions 

94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch) 

Weight 

411 grams(14.5 oz) including batteries (AA*4pcs) 

 

EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

meter, but the performance of the instrument will not be permanently affected.

 

* IP54 Splash Proof 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

n

n

g

g

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

f

f

o

o

r

r

 

 

T

T

I

I

M

M

0

0

3

3

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

I

I

m

m

a

a

g

g

e

e

r

r

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature. 
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report 
generation from these saved images.

 

 

OPERATION 

1.

 

Power on 
Press Mode Key (

2

) or Trigger (

10

) to power on the unit. 

2.

 

Taking a thermal image and temperature 
After  power  on, simply  aim the thermal  imager  camera  at the  measure target  with  Lens 
(

9

)  and  get  the  thermal  image  and  temperature  immediately.  Please  make  sure  the 

target area is within the field of view. 
Note:  There  are three  cursors  on the  screen. The  cross  sign  shows the temperature of 
the  object  located  in  the  middle  of  the  screen.  Other  two  moving  cursors  indicate  the

 

highest and lowest temperatures in the thermal image. 

3.

 

Save thermal images 
Press Trigger (

10

) to save the thermal image to the micro SD card, press Up Key (

3

) or 

Down Key (

4

) to  show the  saved images. Press Mode  Key (

2

) again  to return to the 

measurement screen.

 

4.

 

Color palettes 
Press Color Palette Key (

6

) to select the color palette (4 selectable color palettes) to view thermal images. 

 

 

 

 

Ironbow 

Rainbow 

High contrast 

Grayscale 

5.

 

C/°F/K 

Press Unit Key (

5

) for  C

°F or K transferred. 

6.

 

Power off 

        Press Mode Key (

2

) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..

 

 
FUNCTIONS 

Press  Mode  Key  (

2

)  for  scrolling  more  display  functions,  then  press  Up  key  (

3

)  or  Down  key  (

4

)  to  change  the 

functions, then press Trigger (

10

) to confirm it. 

Emissivity 

The default emissivity is 0.95, or select other default emissivity: Matt:0.95Semi-matt:0.8Semi-glossy:0.6
Glossy:0.3 
Select Set value to adjust the emissivity (0.1 to 1 step .01). 

HAL 

You  can  select  Set  Min  temp  or  Set  Max  item  to  adjust  the  High  Alarm  (HAL)  or  Lo  Alarm  (LAL)  limits 
(step .1). 

LAL 

Language 

Selectable Chinese or English

Backlight 

Selectable 5 levels of brightness. 

Set Time 

Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats. 

Time stamp 

Turn on Time stamp to save thermal images with real-time stamp.   
Turn off Time stamp to hide date and time on stored thermal images. 

Erase Image 

Select Yes, All image! to clear all stored thermal images. 

Reset 

Select Reset to recover the factory setting data. 

Set parameter 

Select Use Median Value

 

to reduce noise in an image. 

Select No Filter

 

to display real image noise. 

 
STORAGE & CLEANING       

It  should  be  stored  at  room  temperature.  The  sensor  lens  is the most  delicate  part  of the  thermometer.  The  lens  should  be  kept 
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. 
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.   

 
BATTERIES
 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. 

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

 

SPECIFICATION 

Thermal Image Resolution 

32*31 

Measurement Range 

-20~250°C (-4~482°F) 

Accuracy (Tamb=20~26°C) 

2% of reading, or 2°C(4°F) whichever is greater 

Thermal Sensitivity 

0.1°C 

Frame Rate 

9Hz 

Field of View 

40*40 deg 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

Focus 

Focus free 

LCD (inch) 

2.8 

LCD Type 

Color 

Image Storage 

Stores up to 60000 images/GB, 

Bitmap (BMP) file format.

 

Memory Type 

Support 8G micro SD card 

Sensor Filter (um) 

8~14um 

Interface 

USB 

Battery Type 

AA*4 

Battery Life (hr)(backlit) 

6   

Dimensions 

94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch) 

Weight 

411 grams(14.5 oz) including batteries (AA*4pcs) 

 

EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

meter, but the performance of the instrument will not be permanently affected.

 

* IP54 Splash Proof 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

n

n

g

g

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

f

f

o

o

r

r

 

 

T

T

I

I

M

M

0

0

3

3

 

 

T

T

h

h

e

e

r

r

m

m

a

a

l

l

 

 

I

I

m

m

a

a

g

g

e

e

r

r

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature. 
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report 
generation from these saved images.

 

 

OPERATION 

1.

 

Power on 
Press Mode Key (

2

) or Trigger (

10

) to power on the unit. 

2.

 

Taking a thermal image and temperature 
After  power  on, simply  aim the thermal  imager  camera  at the  measure target  with  Lens 
(

9

)  and  get  the  thermal  image  and  temperature  immediately.  Please  make  sure  the 

target area is within the field of view. 
Note:  There  are three  cursors  on the  screen. The  cross  sign  shows the temperature of 
the  object  located  in  the  middle  of  the  screen.  Other  two  moving  cursors  indicate  the

 

highest and lowest temperatures in the thermal image. 

3.

 

Save thermal images 
Press Trigger (

10

) to save the thermal image to the micro SD card, press Up Key (

3

) or 

Down Key (

4

) to  show the  saved images. Press Mode  Key (

2

) again  to return to the 

measurement screen.

 

4.

 

Color palettes 
Press Color Palette Key (

6

) to select the color palette (4 selectable color palettes) to view thermal images. 

 

 

 

 

Ironbow 

Rainbow 

High contrast 

Grayscale 

5.

 

C/°F/K 

Press Unit Key (

5

) for  C

°F or K transferred. 

6.

 

Power off 

        Press Mode Key (

2

) for more than 5 sec. to power off the unit. Auto power off time is around 30 sec..

 

 
FUNCTIONS 

Press  Mode  Key  (

2

)  for  scrolling  more  display  functions,  then  press  Up  key  (

3

)  or  Down  key  (

4

)  to  change  the 

functions, then press Trigger (

10

) to confirm it. 

Emissivity 

The default emissivity is 0.95, or select other default emissivity: Matt:0.95Semi-matt:0.8Semi-glossy:0.6
Glossy:0.3 
Select Set value to adjust the emissivity (0.1 to 1 step .01). 

HAL 

You  can  select  Set  Min  temp  or  Set  Max  item  to  adjust  the  High  Alarm  (HAL)  or  Lo  Alarm  (LAL)  limits 
(step .1). 

LAL 

Language 

Selectable Chinese or English

Backlight 

Selectable 5 levels of brightness. 

Set Time 

Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats. 

Time stamp 

Turn on Time stamp to save thermal images with real-time stamp.   
Turn off Time stamp to hide date and time on stored thermal images. 

Erase Image 

Select Yes, All image! to clear all stored thermal images. 

Reset 

Select Reset to recover the factory setting data. 

Set parameter 

Select Use Median Value

 

to reduce noise in an image. 

Select No Filter

 

to display real image noise. 

 
STORAGE & CLEANING       

It  should  be  stored  at  room  temperature.  The  sensor  lens  is the most  delicate  part  of the  thermometer.  The  lens  should  be  kept 
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. 
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.   

 
BATTERIES
 

The thermometer incorporates visual low battery indication as follows: 

 

 

 

‘Battery OK’: measurements 

  are possible 

‘Battery Low’: battery needs to be   

replaced, measurements are still possible 

‘Battery Exhausted’: measurements are 

not possible 

  When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries. 

Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction. 

  Dispose of used battery promptly and keep away from children. 

 

SPECIFICATION 

Thermal Image Resolution 

32*31 

Measurement Range 

-20~250°C (-4~482°F) 

Accuracy (Tamb=20~26°C) 

2% of reading, or 2°C(4°F) whichever is greater 

Thermal Sensitivity 

0.1°C 

Frame Rate 

9Hz 

Field of View 

40*40 deg 

Emissivity Range 

0.95 default – adjustable 0.1 to 1 step .01 

Focus 

Focus free 

LCD (inch) 

2.8 

LCD Type 

Color 

Image Storage 

Stores up to 60000 images/GB, 

Bitmap (BMP) file format.

 

Memory Type 

Support 8G micro SD card 

Sensor Filter (um) 

8~14um 

Interface 

USB 

Battery Type 

AA*4 

Battery Life (hr)(backlit) 

6   

Dimensions 

94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch) 

Weight 

411 grams(14.5 oz) including batteries (AA*4pcs) 

 

EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per 

meter, but the performance of the instrument will not be permanently affected.

 

* IP54 Splash Proof 

 

“Battery OK”:  

Measurements are 

possible

“Battery Low”:  

Battery needs to be replaced, 

measurements are still possible

“Battery Exhausted:  

Measurements are not 

possible

• When the ‘Low Battery’ icon indicates the battery is low, the battery should be recharged  
    by a USB port. 
• Dispose of used batteries properly and keep away from children.
• If the device is not to be used for a long time, turn the power off, remove and store the  
   batteries in a cool, dry place.
• 

Please Note:

 It is important to turn the instrument off before replacing the battery  

   otherwise the thermometer may malfunction

SPECIFICATIONS:

Thermal Image Resolution:

32 x 32

Visual Image Resolution:

640 x 480

Measurement Range:

-20 to 350°C (-4 to 662°F)

Accuracy(Tamb=20~26°C): ±2% of reading, or 2°C (4°F) whichever is greater
Thermal Sensitivity:

0.1°C (0.1˚F)

Frame Rate:

9 Hz

Field of View:

33 x 33 deg 

Emissivity Range:

0.95 default - adjustable 0.1 to 1 (in 0.01 steps)

Focus:

Focus free

LCD (inch):

2.8

LCD type:

Color

Memory Type:

Support micro SD card up to 32 gb (16 gb micro SD card 
provided)

Spectral Range:

8 - 14 um

Interface: 

USB

Battery Type:

3.7 V Li-ion rechargeable battery

Battery Life (with backlight): 3 hrs continuous use
Dimensions:

96.29 x 74.03 x 233.68 mm (3.79 x 2.91 x 9.20 inch)

Weight:

345 grams (12.7 oz) Including batteries

EMC/CRFI: 

Reading may be affected if the unit is operated within radio frequency elec-

tromagnetic field strength of approximately 3 volts per meter, but the performance of the 
instrument will not be permanently affected.