background image

INSTALLATION

 

UK 

4

  All electric cords of domestic appliances near the operating hob should be kept away from the hot 

burners and electric plate.  

  Use protective gloves when removing hot pots and pans from the hob. 

  Keep flammable objects away from burners. 

  Do not put deformed or unstable pots and pans on grates as they can overturn and flood burners. 

  Do not put empty pots and pans on the operating burner or electric plate. 

  Reduce or turn off the flame before removing pots and pans from burners. 

  While in use, the hob must not be left unattended. Never leave the operating device unattended 

especially when frying as overheated oil or fat may ignite. 

  When in use, the hob will produce heat and moisture in the room in which it has been installed. 

Ensure that the room is properly ventilated. Natural ventilation openings should be opened or a 
mechanical ventilation device (cooker hood with extractor) should be installed.  

  Never use the hob to heat a room. 

  It is strictly forbidden to modify the hob so that it can use another type of gas or to make changes in 

the electrical or gas system of the appliance

 

   In case of a gas leakage: 

 

immediately close the valve of the gas system or gas bottle 

 

 

ventilate the room thoroughly 

 

call gas service 

During this time do not: 

 

 

light matches or smoke 

 

 

turn on or turn off electrical devices (radio, door bell, light) or mechanical devices that 
spark. 

   

If the gas coming out of a leaky valve of the gas bottle will ignite, put a wet blanket on the 

bottle to cool it and then close the valve. 

DO NOT USE A DAMAGED GAS BOTTLE! 

  Never use the hob if its supply wire or plug is broken. 

 

Warning ! 
Should you find any crack on the electric plate, immediately disconnect the hob 
from the electric system and call an authorised service personnel. 

 

1.5

 

PREPARATION 

 

1.  Remove all packaging items, including protective layers, from chromed elements and stainless steel 

parts.  

2.  Wipe enamelled surfaces with a soft, damped cloth. 
3.  Make sure that all parts of burners are positioned correctly. 
4.  Before the first use, turn the electric plate ON for approx. 5 minutes by turning the knob to position 

"

6

", exceptionally without any pot or pan. During this time the protective layer on the plate will burn 

out. When the plate has cooled down, wipe the plate with a dry cloth. 

2

 

INSTALLATION 

 

2.1

 

GENERAL NOTES 

 

  

Attention ! 

1.  

This hob must be installed and repaired only by an authorised fitter according to 
the manufacturer’s instructions. 

2.  

Before installation, disconnect the hob from the electric supply. 

Summary of Contents for 2MIE-4GLS B

Page 1: ...2MIE 4GLS X 2MIE 4GLS B CTP O O C BAH C ATA UK PL RU INSTRUCTIONS FOR USE AND MAINTENANCE INSTRUKCJA OBS UGI I U YTKOWANIA...

Page 2: ...ochronnym 8 Wyr b nale y instalowa po 8 godzinach sezonowania w pomieszczeniu kuchennym 9 Urz dzenie to nie jest pod czane do przewod w spalinowych Powinno by ono instalowane i przy czane zgodnie z a...

Page 3: ...P YTY DO BUTLI Z GAZEM P YNNYM 6 2 5 WYMIANA DYSZ 7 2 6 REGULACJA KURK W 8 2 7 POD CZENIE P YTY DO SIECI ELEKTRYCZNEJ 8 3 U YTKOWANIE P YTY 9 3 1 ZASADY EKSPLOATACJI 9 3 2 DOB R P OMIENIA 9 3 3 ZAPAL...

Page 4: ...V 50Hz Palnik AUX 1 0 kW 1 szt Palnik SR 1 75 kW 2 szt Palniki gazowe Palnik R 3 0 kW 1 szt Zapalacze do palnik w Zabezpieczenie przeciwwyp ywowe 1 3 MODELE P YT Pokr t o palnika SR Pokr t o palnika A...

Page 5: ...er bek p yty na inny rodzaj gazu dokonywa zmian w insta lacji gazowej i elektrycznej urz dzenia oraz przenosi je w inne miejsce W przypadku ulatniania si gazu nale y natychmiast zamkn zaw r na instala...

Page 6: ...i p yt gazow powinna wynosi co najmniej 650mm Zabrania si zawieszania szafek kuchennych bezpo rednio nad p yt Je eli pod p yt gazow b dzie umieszczona pozioma przegroda A odleg o pomi dzy p yt i prze...

Page 7: ...y do instalacji gazowej powinno by wykonane zgodnie z obo wi zuj cym prawem przez instalatora posiadaj cego wymagane uprawnienia 2 Przed przyst pieniem do czynno ci pod czania kurek odcinaj cy powinie...

Page 8: ...omienia np zapa k lub wiec Grozi to wybuchem 2 Okresowo nale y sprawdza stan w a i szczelno po czenia zgodnie z obo wi zuj cymi przepisami 2 5 WYMIANA DYSZ UWAGA Przed wymian dysz i przeprowadzeniem...

Page 9: ...niu kurk w za o y pokr t o i zgasi p omie Rys 10 2 7 POD CZENIE P YTY DO SIECI ELEKTRYCZNEJ P yta jest wyposa ona w przew d zasilaj cy bez wtyczki Przed pod czeniem p yty do sieci elektrycznej nale y...

Page 10: ...h naczy Prawid owe i oszcz dne u ytkowanie palnik w uzyskuje si przez ustawienie odpowiedniej wielko ci p omienia prawid owy dob r naczy 2MIE 4GLS X 2MIE 4GLS B Palnik z zabezpieczeniem przeciwwyp ywo...

Page 11: ...t u ywana zaw r butli gazowej powinien by zamkni ty 3 4 GASZENIE PALNIK W Pokr t o kurka gazowego obr ci zgodnie z kierunkiem ruchu wskaz wek zegara i ustawi je na pozycji zerowej oznaczonej 3 5 OBS U...

Page 12: ...tanu technicznego i estetycznego wygl du p yt nale y systematycznie czy ci Do czyszczenia p yty nie nale y stosowa gruboziarnistych rodk w rysuj cych powierzchnie ostrych przedmiot w drucianych g bek...

Page 13: ...il onym w rozpuszczalniku Aby wyczy ci palniki nale y zdj nakrywki i korony palnik w Rys 9 a nast pnie wymoczy je w ciep ej wodzie z detergentem i ka d cz palnika osobno umy Elementy palnik w my g bk...

Page 14: ...nowi pr b zapalenia gazu Palnik nie zapala ga zu Zatkana zalana dysza palnika Wyj wszystkie elementy palnika Wyczy ci i osuszy kielich w kt rym znajduje si dysza Dysz wyczy ci i ewentualnie przetka j...

Page 15: ...PL 14...

Page 16: ...leave this device for 8 hours in the room where it will be installed 10 This hob is not connected to exhaust pipes This hob should be installed and connected according to the valid regulations Specia...

Page 17: ...D GAS BOTTLE 6 2 4 NOZZLE REPLACEMENT 7 2 5 ADJUSTING CONTROL KNOBS 7 2 6 CONNECTING THE HOB TO THE MAINS 8 3 OPERATION 8 3 1 GAS BURNERS 8 3 1 1 Flame adjusting 9 3 1 2 Igniting burners 9 3 1 3 Turni...

Page 18: ...1 0 kW SR burner 1 75 kW Gas burners R burner 3 0 kW Flame failure protection Plates HOBS are made in different colours The following letter symbols are used for different colours X inox B white A an...

Page 19: ...he valve of the gas system or gas bottle ventilate the room thoroughly call gas service During this time do not light matches or smoke turn on or turn off electrical devices radio door bell light or m...

Page 20: ...b on the window door line There should be a free space left over the hob for discharging fumes The best solution is to install a cooker hood which will absorb and discharge these fumes The minimum dis...

Page 21: ...ed with an elbow and seal Fig 11 Connection to the internal gas system should be either rigid or with a flexible metal pipe Gas supply is ended with a shut off cock The shut off cock should be easily...

Page 22: ...sure stated on the appliance s rating plate In the event of a change of the type of gas replace the nozzles and adjust the taps Before beginning these activities you must shut down the cock shutting o...

Page 23: ...ting the hob to the mains make sure that mains voltage complies with data found on the rating plate power of the electric system is sufficient when compared with the power consumption of the hob Atten...

Page 24: ...e control knob position Fig 16 Adjust the flame only between and Flame should not spread beyond the bottom of the vessel but spread on 2 3 of the vessel s bottom This will ensure gas efficiency and th...

Page 25: ...gas bottle valve should be closed when the hob is not used 3 1 5 VESSEL SELECTION Pots should not be too high It is recommended to use vessels whose height is about 2 3 of their bottom diameter Fig 17...

Page 26: ...gent then wash and dry the grates 4 2 CLEANING THE HOB AND BURNERS Fig 20 Fig 21 Before cleaning the hob remove the grates and burner caps and crowns Wipe the enamelled surface of the hot plate using...

Page 27: ...ut by an authorised service workshop After the warranty period a user should have the appliance inspected by a service shop regularly Table 3 Symptoms Causes Troubleshooting Igniters fail to ignite or...

Page 28: ...NMENT PROTECTION This appliance is marked with a symbol of a crossed out wheeled bin in compliance with the European Directive 2002 96 EC This symbol means that the appliance when its economic life is...

Page 29: ..._______ ___________ _____________ _______________________________________________________________________________ __________________________________________ ___________________________________________...

Page 30: ...RU 2 1 2 3 4 5 6 7 8 I 9 8 10 11 12 13 1 73 23 EEC 2 89 336 EEC 3 90 396 EEC GAD...

Page 31: ...RU 3 1 4 1 1 4 1 2 4 1 3 4 1 4 4 2 5 2 1 5 2 2 6 2 3 7 2 4 7 2 5 8 2 6 9 2 7 9 3 10 3 1 10 3 2 10 3 3 11 3 4 11 3 5 11 3 6 11 4 12 4 1 12 4 2 13 5 13...

Page 32: ...RU 4 1 1 1 1 2 1 2MIE 4GLS X 2MIE 4GLS B 90 590 515 230 50 AUX 1 0 1 SR 1 75 2 R 3 0 1 1 3 2MIE 4GLS X 2MIE 4GLS B 1 1 4...

Page 33: ...RU 5 2 2 1 1 2 30 2...

Page 34: ...RU 6 100 650 150 3 2 3 2 2 1 490 560 4 2 3 5 4 5 150 650 100 30 6 0...

Page 35: ...RU 7 4 5 6 7 6 3 6 7 2 3 1 2 8 8 2 4...

Page 36: ...RU 8 1 2 2 5 2 2 AUX SR R 2H G 20 13 084 110 145 2H G 20 20 X072 Z097 Y118 3B P G 30 30 050 065 085 2 9...

Page 37: ...RU 9 2 6 10 10 2 4 2 7 1 2 3...

Page 38: ...RU 10 3 3 1 2MIE 4GLS X 2MIE 4GLS B 11 3 2 12 0 12 13 13 2 3...

Page 39: ...RU 11 3 3 2MIE 4GLS X 2MIE 4GLS B 10 5 3 4 3 5 3 6 2 3 GR R SR AUX 18 28 16 26 14 22 12 16...

Page 40: ...RU 12 14 15 16 4 4 1...

Page 41: ...RU 13 4 2 17 18 20 21 9 5 3...

Page 42: ...RU 14 3 b 1 2 3...

Page 43: ...B E CPE A 2002 96...

Page 44: ...07 2010 C600992I3...

Reviews: