MCA Alliance Series 

 

Combination Filter and Softener

 

 

 

2022 Version

 

MASTER

Water Conditioning Corp.

Installation and Operation Manual

 

Summary of Contents for CFES-20T

Page 1: ...MCAAlliance Series Combination Filter and Softener 2022 Version MASTER Water Conditioning Corp Installation and Operation Manual...

Page 2: ...Positioning 1 Control Valve 2 Service and Drain Piping 3 5 Electrical Requirements 6 Brine Tank 6 Filling Softener with Water 7 Control Valve Timer Settings 8 Final Check 9 Manual Regeneration 9 Bypa...

Page 3: ...ES 20T CF Birm CFES 30T 1 CF Birm CFES 40T 1 CF Birm CNS 20T CF NS Mix CNS 30T CF Calcite CF NS Mix CNS 40T CF Calcite CF NS Mix CTS 20T CF Activated Carbon CTS 30T 1 CF Activated Carbon CTS 40T 1 CF...

Page 4: ...f the tank See page one for your specific model number unit to determine the amount of media to load into the mineral tank 5 Remove the material used to cover the top opening of the distributor pipe C...

Page 5: ...rder Each tail piece o ring split ring and nut is presassembled at the factory Align a tail piece assembly to the bypass valve threaded inlet and insert until the nut can be tightened Hand tighten the...

Page 6: ...be of adequate size to allow for full regeneration flow The control valve drain connection is 3 4 npt Never decrease the drain piping size to below drain connection size Maximum drain line length is...

Page 7: ...Water Conditioners must be installed after the well tank or water meter if its public water supply Brine tank Air Gap Drain Overflow fitting to floor drain gravity Untreated TYPICAL PIPING LAYOUT FOR...

Page 8: ...ovides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The brine tank should be located directly besid...

Page 9: ...F WATER ENTERS THE TANK TOO FAST ALL THE CATION RESIN WILL BE FLUSHED TO DRAIN DURING START UP 4 When only water is running to the drain open the inlet and outlet ball valves fully 5 Press the Up butt...

Page 10: ...button Time of Regeneration Setting the factory default is 2 AM Simultaneously press the CLOCK and the UP arrow for 3 seconds The screen will display Set Time Regen and the hour will be blinking 1 Us...

Page 11: ...e the drain line connection meets all plumbing codes and that the drain line size can handle the backwash flow rate of the softener 3 Make sure the Inlet and Outlet on bypass valve are open 4 Make sur...

Page 12: ...10...

Page 13: ...r pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Check flow rate capabilities of...

Page 14: ...o height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Problem Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control R...

Page 15: ...ral bed with cleaner Slots in riser pipe or laterals are filled with resin fines Inspect and clean distributor pipe slots as needed Problem Salt in Water to Service after Regeneration Possible Cause S...

Page 16: ...tes at wrong time of day Possible Cause Solution Power Outages Reset control valve to correct time of day Time of day not set correctly Reset to correct time of day Time of regeneration incorrect Rese...

Page 17: ...c power at outlet Repair outlet or use working outlet Broken drive gear or drive cap assembly Replace drive gear assembly Defective PC board Replace PC board Problem Control valve does not regenerate...

Page 18: ...or mechanical stall Defective motor damaged wiring poor wire connection or mechanical component failure E3 1003 Motor running too long or timeout during piston relocating Damaged wiring poor wire con...

Page 19: ...17...

Page 20: ...18...

Page 21: ...19...

Page 22: ...20...

Page 23: ...21...

Page 24: ...22...

Page 25: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Page 26: ...C4 Rinse C5 Brine Refill P0 3 50 3 3 1 99 P1 8 50 8 4 1 99 P2 8 70 10 6 1 99 P3 12 70 12 8 1 99 P4 10 50 Skipped 8 CNS 20 10 CNS 30 10 CNS 40 14 P5 4 50 Skipped 4 1 99 P6 12 6 Skipped 12 1 99 P7 6 Sk...

Page 27: ...TH A DP SWITCH OR CLOCK CLOCK CLOCK REGENERATE NOW PRESS BOTH ARROWS FOR 4 SECONDS MOTOR WILL START REGENERATE TONIGHT PRESS BOTH ARROWS FOR 1 SECOND MANUAL REGENERATION AND SIMULTANEOUSLY ADVANCE THR...

Page 28: ...Regen d1 Do not Regen OR d2 Regen Regen d2 Do not Regen CHOOSE REGEN DAY OF WEEK MONDAY CONTINUE THROUGH d7 OR Display Day of Week D1 Sunday D2 Monday D3 Tuesday D4 Wednesday D5 Thursday D6 Friday D7...

Page 29: ...3 SECONDS 1 Regen Hour SET HOUR OF DAY FOR REGENERATION 4 Days to Regen SET DAYS BETWEEN REGENERATIONS 1 99 DAY OPTION CLOCK AND OR OR CLOCK 00 Regen Hour SET MINUTES OF DAY FOR REGENERATION OR CLOCK...

Page 30: ...Error Codes...