en
Figures and texts of this book are protected by COPYRIGHT.
►3.4.4. For proper operation it is crucial
to connect the earth to the cooler properly.
►3.4.5. Connect the control panel, using
the specific connector (Pic. 5).
NOTE: WE RECOMMEND USING A 2P
10A DIFFERENTIAL SWITCH.
►3.5. INSTALLING THE DRAIN
VALVE
(Pic. 6)
At the base of the cooler, to drain water
from the tank, the cooler is equipped with
a drain valve.
At the time of purchase, the drain valve
comes in the kit supplied.
To install the valve you must:
►3.5.1. Remove the nut installed at the
base of the valve.
►3.5.2. Insert the valve into its seat
(located at the base of the cooler).
►3.5.3. Screw the nut back onto the
valve.
►3.6. CONNECTING TO THE WATER
MAINS
(Pic. 7)
IMPORTANT: ONLY FEED THE
COOLER WITH CLEAN WATER.
IMPORTANT: THE COOLER CAN
WITHSTAND A MAXIMUM WATER
INLET PRESSURE OF 3 BAR. THE
PIPES AND FITTINGS USED FOR
THE WATER SUPPLY MUST BE
OF ADEQUATE SECTION AND
STRUCTURE (IF THE PRESSURE
OF THE WATER MAINS IS HIGH, WE
RECOMMEND USING A PRESSURE
REDUCER AND A METAL MESH PIPE).
►3.6.1. Connect the cooler to the water
mains using the threaded fitting.
►3.6.2. Make sure that there are no water
leaks in the circuit before commissioning.
►3.7. BASIC CONFIGURATION
(Pic. 8)
IMPORTANT: THE BASIC
CONFIGURATION OF THE COOLER
MUST BE CARRIED OUT FROM
THE CONTROL PANEL. THE
CONFIGURATION MUST BE CARRIED
OUT WITH THE COOLER SWITCHED
OFF, BUT POWERED FROM THE
ELECTRICAL MAINS.
►
DRAIN: (Press and hold the DRAIN
button for a few seconds): You can then
access the sub-menu that allows you
to set every how many hours the cooler
must automatically drain the water from
the tank (with the value at “0” the tank
is never drained automatically).
►
VENTOLA (FAN): (Press and hold
the VENTOLA (FAN) button for a few
seconds): You can then access the sub-
menu that allows you to set the direction
of fan rotation [(0= clockwise, to let air
into the room) (1= anticlockwise, to let
air out of the room)].
►►4. ANOMALIES
WARNING: Carefully read the
“SAFETY INFORMATION” before
switching on the cooler.
WARNING: Only use clean water to
prevent failures or other anomalies.
WARNING: Verify if your electronic
system is earthed correctly.
Connection to the electrical mains
must be carried out in compliance
with the national standards in force.
Only power the appliance the with
voltage and frequency as specified on
the nameplate.