Quickly turn the engine several times in the running direction, in order to distribute the oil evenly.  

Meticulous maintenance and care should include the check of the oil level prior to each use. To 

carry out this check, please use the dipstick provided. During the check the unit has to stand level 

and must be switched off and cooled down. Please make absolutely sure that the oil level is within 

the indicated minimum and maximum limits. Please observe the local regulations regarding the 

disposal of waste oil.  

 

6.2.          Automatic activation of the low-oil auto-stop feature 

The pump is equipped with a low-oil safety feature. The models with auto-lubrication are equipped 

with an autostop feature. This handy feature will automatically cut out the engine in case the motor 

oil  level  drops  below  the    required  minimum.  In  this  case  starting  the  motor  again  is  impossible 

until  a  sufficient  quantity  of  motor  oil  has  been  topped  up.  When  topping  up  motor  oil,  please 

observe all information contained in this manual regarding motor oil and oil level check.  

 

6.3.          Spark plug 

Cleaning the spark plug and, where necessary, an adjustment of the electrode gaps should be 

performed at intervals of six months or 100 hours of operation. 

maintenance on the spark plug 

please pull off the spark plug socket first. Then use a spark plug wrench to remove the spark plug. 

For a disturbance-free functioning the spark plug has to be dry and free of combustion residues, 

and the electrode gap must be between 0.6-0.7 mm.  

If required, please clean the spark plug. We recommend to use a fine-wire brush to remove 

combustion residues.  

Where needed, correct the electrode gap by carefully bending the electrode. In the case of 

excessive deposits or worn electrodes you should insert a new spark plug.  

Manually screw in the inspector, clean or, possibly, new spark plug until it comes to a stop. Then 

tighten the spark plug carefully using the spark plug wrench. Please do not use excessive force in 

order to avoid overtightening and consequently damaging the spark plug. To complete your work, 

slip the spark plug connector on the spark plug.

 

 

 

 

 

 

 

Summary of Contents for MPG7HP24

Page 1: ...MPG7HP24 GB ENGINE DRIVEN PUMP TRANSLATION OF THE ORIGINAL INSTRUCTIONS...

Page 2: ...ge caused as a result of the nonobservance of instructions and provisions of the present operating instructions Any damage caused as a result of the nonobservance of the instructions and regulations c...

Page 3: ...not smoke or work near the machine 3 Check regularly all fuel lines and tank for any leaks and cracks 4 Switch of the engine if the machine gets filled with fuel 5 Do not refuel if the machine is runn...

Page 4: ...informed immediately at the latest within 8 days after the date of purchase SYMBOLES Compliance with appropriate safety standards Read the instruction manual before starting the engine and using your...

Page 5: ...re portable self priming pumps operated with petrol or a petrol oil mixture depending on the model These high quality products with their convincing performance data were developed especially for main...

Page 6: ...ine air cooled Speed 3840 min 1 Tank volume 2 0 L fuel Petrol unleaded RON 95 98 Maximum operating time 1 5h Oil capacity 400 ml Maximum flow 117 L min 7m h Max delivery height Hmax 30 m Max suction h...

Page 7: ...ction pipes you should make sure that the pump is not exposed to any form of weight vibration or tension 4 2 Installation of the intake line The inlet of the intake line is to be equipped with a filte...

Page 8: ...r stationary installation please fasten the pump on a suitable solid surface 5 PUTTING INTO OPERATION 5 1 Set up and visual inspection The exhaust gases of petrol engine pumps contain toxic odourless...

Page 9: ...del being used petrol engine pumps from MASTER PUMPS are operated with petrol or a petrol oil mixture The required type of fuel is stated in the technical details of the specific model Please do not u...

Page 10: ...o in the technical details Low oil safety feature The low oil safety feature serves to avoid damage to the engine in case there is insufficient engine oil in the crankcase Before the engine oil level...

Page 11: ...e of water This so called dry running i e the operation of the pump without any water being discharged may cause considerable damage to the unit The petrol engine pump including the entire line system...

Page 12: ...s of the engine too become hot during operation Therefore please avoid to touch the unit during operation and afterwards from power off to its cooling down at any points other than those intended for...

Page 13: ...mage to the engine and downtimes Abrasive matters contained in the liquid being discharged such as sand accelerate wear and tear and reduce the performance of the pump When discharging liquids contain...

Page 14: ...please observe all information contained in this manual regarding motor oil and oil level check 6 3 Spark plug Cleaning the spark plug and where necessary an adjustment of the electrode gaps should b...

Page 15: ...se open the air filter box and take the filter out If necessary wash out the air filter in a non combustible solvent such as a washing up liquid dishwashing detergent For reason of the fire or explosi...

Page 16: ...drained as well Prior to placing the unit in storage it should be cleaned thoroughly and afforded some kind of preservation should this be advisable Please make sure that the device is stored in a dry...

Page 17: ...tape Replace intake line if it shows damage which cannot be repaired 3 Increase motor performance 4 Clean filter 5 Clean intake line 6 Remove foreign matters 7 Modify the arrangement so that the suct...

Page 18: ...materials or manufacturing will be eliminated free of charge Any complaints are to be reported immediately upon their detection The warranty claim becomes void in the case of interventions undertaken...

Page 19: ...you have to take or send in your defective device for repair please remove any attached parts which do not belong to the original condition of the device If any attached parts of this kind should be m...

Page 20: ...ng system after the end of their life cycle When disposing of this product make sure that the fuel and oil are drained from the engine Should you have any questions please contact your local waste dis...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...overeenstemming MASTER PUMPS verklaart dat de machines THERMISCHE OPPERVLAKTEPOMP MPG7HP24 in overeenstemming zijn met de volgende normen EN 809 1998 A1 2009 AfPS GS 2014 01 PAK EN 55012 2007 A1 2009...

Page 26: ...o V Belgium in January 2019 Mr Joostens Pierre Director MASTER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique EG Konformit tserkl rung MASTER PUMPS erkl rt hiermit da der GASOLENE WATER PUMP...

Page 27: ...9 Mr Joostens Pierre Direttore MASTER PUMPS rue de Goz e 81 6110 Montigny le Tilleul Belgique Declaraci n CE de conformidad MASTER PUMPS declara que las m quinas GASOLENE WATER PUMP MPG7HP24 han sido...

Page 28: ...0032 71 29 70 86 S A V sav eco repa com Service Parts separated 32 71 29 70 83 32 71 29 70 86 Fabriqu en Chine Vervaardigd in China Made in China Hergestellt in China Fabbricato in Cina Import par Ge...

Reviews: